MIN 4600TL-XH leads on the differences that matter

The largest is european efficiency: 2.9 pp more efficient. 12 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Growatt MIN 4600TL-XH](https://comparepv.com/inverter/growatt-min-4600tl-xh) | [Sofar Solar HYD 4600-EP](https://comparepv.com/inverter/sofar-solar-hyd-4600-ep) |
| Manufacturer | Growatt | Sofar Solar |
| Rated AC power | 4.6 kW | 4.6 kW |
| Type | Hybrid | Hybrid |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | MIN 4600TL-XH | HYD 4600-EP | Difference |
| --- | --- | --- | --- |
| European efficiency | 97.5 % | 94.6 % | +2.9 pp for MIN 4600TL-XH |
| Max DC voltage | 550 V | 600 V | 50 V apart |
| Max efficiency | 98.4 % | 97.8 % | +0.6 pp for MIN 4600TL-XH |
| Max PV power | 9.20 kW | 6.90 kW | 2.30 kW apart |
| DC/AC ratio | 2.00 | 1.50 | +0.50 for MIN 4600TL-XH |
| Max charge current | 17 A | 100 A | +83 A for HYD 4600-EP |
| Weight | 10.8 kg | 21.5 kg | -10.7 kg for MIN 4600TL-XH |
| Weight per kW | 2.3 kg/kW | 4.7 kg/kW | -2.3 kg/kW for MIN 4600TL-XH |
| MPP trackers | 2 | 1 | +1 trackers for MIN 4600TL-XH |
| Max input current per tracker | 13.5 A | 13.0 A | +0.5 A for MIN 4600TL-XH |
| MPPT voltage range | 70-550 V | 90-550 V | 70-550 V vs 90-550 V |
| Battery voltage | 360-550V | 42-58 Vdc | 360-550V vs 42-58 Vdc |
| Max AC current | 20.9 A | 20.0 A | 0.9 A apart |
| Dimensions | 350x375x160 mm | 503x482x183 mm | 350x375x160 mm vs 503x482x183 mm |


## Every compared parameter


| Parameter | MIN 4600TL-XH | HYD 4600-EP |
| --- | --- | --- |
| Rated AC power | 4.60 kW | 4.60 kW |
| Max AC power | 4.60 kW | 4.60 kW |
| Grid connection | Single-phase | Single-phase |
| Nominal AC voltage | 230 V | 230 V |
| Max AC current | 20.9 A | 20.0 A |
| Max PV power | 9.20 kW | 6.90 kW |
| DC/AC ratio | 2.00 | 1.50 |
| Max DC voltage | 550 V | 600 V |
| MPPT voltage range | 70-550 V | 90-550 V |
| Start voltage | 100 V | 100 V |
| MPP trackers | 2 | 1 |
| Strings per tracker | 1 | 1 |
| Max input current per tracker | 13.5 A | 13.0 A |
| European efficiency | 97.5 % | 94.6 % |
| Max efficiency | 98.4 % | 97.8 % |
| CEC efficiency | - | - |
| Battery input | Yes | Yes |
| Battery voltage | 360-550V | 42-58 Vdc |
| Max charge current | 17 A | 100 A |
| Backup power | - | - |
| Weight | 10.8 kg | 21.5 kg |
| Weight per kW | 2.3 kg/kW | 4.7 kg/kW |
| Dimensions | 350x375x160 mm | 503x482x183 mm |
| Ingress protection | IP65 | IP65 |
| Cooling | natural | natural |
| Noise | - | - |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | Yes | Yes |
| Ethernet | Yes | - |
| Arc fault protection | Yes | - |
| Integrated DC switch | Yes | Yes |
| Warranty | 5 yrs | - |


## Related comparisons

- [Growatt MIN 4600TL-XH vs Huawei SUN2000L-4.6KTL](https://comparepv.com/compare-inverters/growatt-min-4600tl-xh/huawei-sun2000l-4-6ktl) - 11 differences, the largest is european efficiency
- [Growatt MIN 4600TL-XH vs Huawei SUN2000-4.6KTL-L1](https://comparepv.com/compare-inverters/growatt-min-4600tl-xh/huawei-sun2000-4-6ktl-l1) - 12 differences, the largest is max dc voltage
- [Growatt MIN 4600TL-XH vs Growatt SPM 4600TL-HU](https://comparepv.com/compare-inverters/growatt-min-4600tl-xh/growatt-spm-4600tl-hu) - 13 differences, the largest is max dc voltage


---

Source: https://comparepv.com/compare-inverters/growatt-min-4600tl-xh/sofar-solar-hyd-4600-ep

Not in this file, on the page: a written summary generated on request.