# Growatt MIN 2500TL-XH vs Growatt MIN 2500TL-XH2

MIN 2500TL-XH2 leads on the differences that matter

The largest is max input current per tracker: 2.5 A more headroom. 24 of 29 comparable parameters are identical, with 3 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Growatt MIN 2500TL-XH](https://comparepv.com/inverter/growatt-min-2500tl-xh) | [Growatt MIN 2500TL-XH2](https://comparepv.com/inverter/growatt-min-2500tl-xh2) |
| Manufacturer | Growatt | Growatt |
| Rated AC power | 2.5 kW | 2.5 kW |
| Type | Hybrid | Hybrid |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | MIN 2500TL-XH | MIN 2500TL-XH2 | Difference |
| --- | --- | --- | --- |
| Max input current per tracker | 13.5 A | 16.0 A | +2.5 A for MIN 2500TL-XH2 |
| Start voltage | 100 V | 50 V | -50 V for MIN 2500TL-XH2 |
| Ingress protection | IP65 | IP66 | IP65 vs IP66 |
| MPPT voltage range | 70-550 V | 40-540 V | 70-550 V vs 40-540 V |
| Battery voltage | 360-550V | 360-550 V | 360-550V vs 360-550 V |


## Every compared parameter


| Parameter | MIN 2500TL-XH | MIN 2500TL-XH2 |
| --- | --- | --- |
| Rated AC power | 2.50 kW | 2.50 kW |
| Max AC power | 2.50 kW | 2.50 kW |
| Grid connection | Single-phase | Single-phase |
| Nominal AC voltage | 230 V | 230 V |
| Max AC current | 11.3 A | 11.3 A |
| Max PV power | 5.00 kW | 5.00 kW |
| DC/AC ratio | 2.00 | 2.00 |
| Max DC voltage | 550 V | 550 V |
| MPPT voltage range | 70-550 V | 40-540 V |
| Start voltage | 100 V | 50 V |
| MPP trackers | 2 | 2 |
| Strings per tracker | 1 | 1 |
| Max input current per tracker | 13.5 A | 16.0 A |
| European efficiency | 97.1 % | 97.1 % |
| Max efficiency | 98.2 % | 98.2 % |
| CEC efficiency | - | - |
| Battery input | Yes | Yes |
| Battery voltage | 360-550V | 360-550 V |
| Max charge current | 17 A | 17 A |
| Backup power | - | - |
| Weight | 10.8 kg | 10.8 kg |
| Weight per kW | 4.3 kg/kW | 4.3 kg/kW |
| Dimensions | 350x375x160 mm | 350x375x160 mm |
| Ingress protection | IP65 | IP66 |
| Cooling | natural | natural |
| Noise | - | - |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | Yes | Yes |
| Ethernet | Yes | Yes |
| Arc fault protection | Yes | Yes |
| Integrated DC switch | Yes | Yes |
| Warranty | 5 yrs | 5 yrs |


## Related comparisons

- [Growatt MIN 2500TL-XH vs SolarEdge SE2500H](https://comparepv.com/compare-inverters/growatt-min-2500tl-xh/solaredge-se2500h) - 7 differences, the largest is european efficiency
- [Growatt MIN 2500TL-XH vs Growatt MIN 2500TL-XA](https://comparepv.com/compare-inverters/growatt-min-2500tl-xh/growatt-min-2500tl-xa) - 2 differences, the largest is warranty
- [Growatt MIN 2500TL-XH vs Easun Power IGrid SV LV-3K-24](https://comparepv.com/compare-inverters/growatt-min-2500tl-xh/easun-power-igrid-sv-lv-3k-24) - 9 differences, the largest is max efficiency


---

Source: https://comparepv.com/compare-inverters/growatt-min-2500tl-xh/growatt-min-2500tl-xh2

Not in this file, on the page: a written summary generated on request.