# Growatt MID 15KTL3-X vs Sungrow SG15RT-P2

MID 15KTL3-X leads on the differences that matter

The largest is european efficiency: 0.7 pp more efficient. 14 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Growatt MID 15KTL3-X](https://comparepv.com/inverter/growatt-mid-15ktl3-x) | [Sungrow SG15RT-P2](https://comparepv.com/inverter/sungrow-sg15rt-p2) |
| Manufacturer | Growatt | Sungrow |
| Rated AC power | 15 kW | 15 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | MID 15KTL3-X | SG15RT-P2 | Difference |
| --- | --- | --- | --- |
| European efficiency | 98.6 % | 97.9 % | +0.7 pp for MID 15KTL3-X |
| Max efficiency | 98.8 % | 98.3 % | +0.5 pp for MID 15KTL3-X |
| Max AC power | 16.60 kW | 16.50 kW | 0.10 kW apart |
| Start voltage | 250 V | 180 V | -70 V for SG15RT-P2 |
| Weight | 23.0 kg | 22.0 kg | -1.0 kg for SG15RT-P2 |
| MPPT voltage range | 200-1000 V | 160-1000 V | 200-1000 V vs 160-1000 V |
| Max AC current | 24.2 A | 25.0 A | 0.8 A apart |
| Dimensions | 395x525x222 mm | 480x370x195 mm | 395x525x222 mm vs 480x370x195 mm |


## Every compared parameter


| Parameter | MID 15KTL3-X | SG15RT-P2 |
| --- | --- | --- |
| Rated AC power | 15.00 kW | 15.00 kW |
| Max AC power | 16.60 kW | 16.50 kW |
| Grid connection | 3-phase | 3-phase |
| Nominal AC voltage | 400 V | 400 V |
| Max AC current | 24.2 A | 25.0 A |
| Max PV power | 22.50 kW | 22.50 kW |
| DC/AC ratio | 1.50 | 1.50 |
| Max DC voltage | 1100 V | 1100 V |
| MPPT voltage range | 200-1000 V | 160-1000 V |
| Start voltage | 250 V | 180 V |
| MPP trackers | 2 | 2 |
| Strings per tracker | - | 2 |
| Max input current per tracker | - | 32.0 A |
| European efficiency | 98.6 % | 97.9 % |
| Max efficiency | 98.8 % | 98.3 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | 23.0 kg | 22.0 kg |
| Weight per kW | 1.5 kg/kW | 1.5 kg/kW |
| Dimensions | 395x525x222 mm | 480x370x195 mm |
| Ingress protection | IP65 | IP65 |
| Cooling | forced-air | forced-air |
| Noise | - | - |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | Yes | Yes |
| Ethernet | Yes | Yes |
| Arc fault protection | - | Yes |
| Integrated DC switch | Yes | Yes |
| Warranty | 5 yrs | - |


## Related comparisons

- [Growatt MID 15KTL3-X vs Sungrow SG15KTL-M](https://comparepv.com/compare-inverters/growatt-mid-15ktl3-x/sungrow-sg15ktl-m) - 4 differences, the largest is max ac power
- [Growatt MID 15KTL3-X vs Huawei SUN2000-15KTL-M2](https://comparepv.com/compare-inverters/growatt-mid-15ktl3-x/huawei-sun2000-15ktl-m2) - 9 differences, the largest is weight
- [Growatt MID 15KTL3-X vs Huawei SUN2000-15KTL-M0](https://comparepv.com/compare-inverters/growatt-mid-15ktl3-x/huawei-sun2000-15ktl-m0) - 9 differences, the largest is weight


---

Source: https://comparepv.com/compare-inverters/growatt-mid-15ktl3-x/sungrow-sg15rt-p2

Not in this file, on the page: a written summary generated on request.