# Growatt 2500-S vs Growatt MIN 2500TL-X

Growatt 2500-S leads on the differences that matter

The largest is max efficiency: 0.6 pp more efficient. 12 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Growatt 2500-S](https://comparepv.com/inverter/growatt-growatt-2500-s) | [Growatt MIN 2500TL-X](https://comparepv.com/inverter/growatt-min-2500tl-x) |
| Manufacturer | Growatt | Growatt |
| Rated AC power | 2.5 kW | 2.5 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | Growatt 2500-S | MIN 2500TL-X | Difference |
| --- | --- | --- | --- |
| Max efficiency | 97.6 % | 98.2 % | +0.6 pp for MIN 2500TL-X |
| Noise | 25 dB | 35 dB | -10 dB for Growatt 2500-S |
| Weight | 9.1 kg | 10.8 kg | -1.7 kg for Growatt 2500-S |
| Weight per kW | 3.6 kg/kW | 4.3 kg/kW | -0.7 kg/kW for Growatt 2500-S |
| European efficiency | 97.3 % | 97.1 % | +0.2 pp for Growatt 2500-S |
| Max PV power | 3.25 kW | 3.50 kW | 0.25 kW apart |
| Start voltage | 50 V | 100 V | -50 V for Growatt 2500-S |
| MPP trackers | 1 | 2 | +1 trackers for MIN 2500TL-X |
| DC/AC ratio | 1.30 | 1.40 | +0.10 for MIN 2500TL-X |
| Max input current per tracker | 13.0 A | 13.5 A | +0.5 A for MIN 2500TL-X |
| Max AC current | 11.9 A | 11.3 A | 0.6 A apart |
| Dimensions | 359x271x141 mm | 350x375x160 mm | 359x271x141 mm vs 350x375x160 mm |


## Every compared parameter


| Parameter | Growatt 2500-S | MIN 2500TL-X |
| --- | --- | --- |
| Rated AC power | 2.50 kW | 2.50 kW |
| Max AC power | 2.50 kW | 2.50 kW |
| Grid connection | Single-phase | Single-phase |
| Nominal AC voltage | 230 V | 230 V |
| Max AC current | 11.9 A | 11.3 A |
| Max PV power | 3.25 kW | 3.50 kW |
| DC/AC ratio | 1.30 | 1.40 |
| Max DC voltage | 550 V | - |
| MPPT voltage range | 50-550 V | - |
| Start voltage | 50 V | 100 V |
| MPP trackers | 1 | 2 |
| Strings per tracker | 1 | 1 |
| Max input current per tracker | 13.0 A | 13.5 A |
| European efficiency | 97.3 % | 97.1 % |
| Max efficiency | 97.6 % | 98.2 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | 9.1 kg | 10.8 kg |
| Weight per kW | 3.6 kg/kW | 4.3 kg/kW |
| Dimensions | 359x271x141 mm | 350x375x160 mm |
| Ingress protection | IP65 | IP65 |
| Cooling | natural | natural |
| Noise | 25 dB | 35 dB |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | Yes | Yes |
| Ethernet | Yes | Yes |
| Arc fault protection | - | Yes |
| Integrated DC switch | Yes | Yes |
| Warranty | 5 yrs | 5 yrs |


## Related comparisons

- [Growatt 2500-S vs Sungrow SG2.5RS-S](https://comparepv.com/compare-inverters/growatt-growatt-2500-s/sungrow-sg2-5rs-s) - 10 differences, the largest is max dc voltage
- [Growatt 2500-S vs GoodWe GW2500-XS](https://comparepv.com/compare-inverters/growatt-growatt-2500-s/goodwe-gw2500-xs) - 8 differences, the largest is max dc voltage
- [Growatt 2500-S vs Growatt MIC 2500TL-X](https://comparepv.com/compare-inverters/growatt-growatt-2500-s/growatt-mic-2500tl-x) - 6 differences, the largest is weight


---

Source: https://comparepv.com/compare-inverters/growatt-growatt-2500-s/growatt-min-2500tl-x

Not in this file, on the page: a written summary generated on request.