# GoodWe GW23K-SDT-CN-G40 vs SOFAR 23KTLX-G3P

GW23K-SDT-CN-G40 leads on the differences that matter

The largest is nominal ac voltage: 20 V apart. 11 of 15 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [GoodWe GW23K-SDT-CN-G40](https://comparepv.com/inverter/goodwe-gw23k-sdt-cn-g40) | [SOFAR 23KTLX-G3P](https://comparepv.com/inverter/sofar-solar-sofar-23ktlx-g3p) |
| Manufacturer | GoodWe | Sofar Solar |
| Rated AC power | 23 kW | 23 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | GW23K-SDT-CN-G40 | SOFAR 23KTLX-G3P | Difference |
| --- | --- | --- | --- |
| Nominal AC voltage | 380 V | 400 V | 20 V apart |
| MPPT voltage range | 140-1000 V | 160-1000 V | 140-1000 V vs 160-1000 V |
| Start voltage | 160 V | 180 V | -20 V for GW23K-SDT-CN-G40 |
| Dimensions | 413x530x211 mm | 412x491x188 mm | 413x530x211 mm vs 412x491x188 mm |


## Every compared parameter


| Parameter | GW23K-SDT-CN-G40 | SOFAR 23KTLX-G3P |
| --- | --- | --- |
| Rated AC power | 23.00 kW | 23.00 kW |
| Max AC power | 25.30 kW | 25.30 kW |
| Grid connection | 3-phase | 3-phase |
| Nominal AC voltage | 380 V | 400 V |
| Max AC current | 38.4 A | 38.5 A |
| Max PV power | - | - |
| DC/AC ratio | - | - |
| Max DC voltage | 1100 V | 1100 V |
| MPPT voltage range | 140-1000 V | 160-1000 V |
| Start voltage | 160 V | 180 V |
| MPP trackers | 2 | 2 |
| Strings per tracker | 2 | - |
| Max input current per tracker | 21.0 A | - |
| European efficiency | - | 98.1 % |
| Max efficiency | 98.7 % | 98.6 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | 17.0 kg | - |
| Weight per kW | 0.7 kg/kW | - |
| Dimensions | 413x530x211 mm | 412x491x188 mm |
| Ingress protection | IP66 | IP66 |
| Cooling | forced-air | forced-air |
| Noise | 45 dB | - |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | - | Yes |
| Ethernet | - | - |
| Arc fault protection | - | - |
| Integrated DC switch | Yes | Yes |
| Warranty | - | - |


## Related comparisons

- [GoodWe GW23K-SDT-CN-G40 vs Sungrow SG23T-P2-CN](https://comparepv.com/compare-inverters/goodwe-gw23k-sdt-cn-g40/sungrow-sg23t-p2-cn) - 7 differences, the largest is max input current per tracker
- [GoodWe GW23K-SDT-CN-G40 vs Ginlong Solis S5-GC23K-LV](https://comparepv.com/compare-inverters/goodwe-gw23k-sdt-cn-g40/ginlong-solis-s5-gc23k-lv) - 10 differences, the largest is max input current per tracker
- [GoodWe GW23K-SDT-CN-G40 vs Ginlong Solis S6-GC3P23K03-LV-ND](https://comparepv.com/compare-inverters/goodwe-gw23k-sdt-cn-g40/ginlong-solis-s6-gc3p23k03-lv-nd) - 11 differences, the largest is max input current per tracker


---

Source: https://comparepv.com/compare-inverters/goodwe-gw23k-sdt-cn-g40/sofar-solar-sofar-23ktlx-g3p

Not in this file, on the page: a written summary generated on request.