# Solis-60K-4G vs SolarEdge SE100K (for 220V/230V line-to-line grids)

Solis-60K-4G leads on the differences that matter

The largest is rated ac power: 2.30 kW apart. 5 of 15 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Solis-60K-4G](https://comparepv.com/inverter/ginlong-solis-solis-60k-4g) | [SolarEdge SE100K (for 220V/230V line-to-line grids)](https://comparepv.com/inverter/solaredge-se100k-for-220v-230v-line-to-line-grids) |
| Manufacturer | Ginlong Solis | SolarEdge |
| Rated AC power | 60 kW | 57.7 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | Solis-60K-4G | SE100K (for 220V/230V line-to-line grids) | Difference |
| --- | --- | --- | --- |
| Rated AC power | 60.00 kW | 57.70 kW | 2.30 kW apart |
| European efficiency | 98.5 % | 98.0 % | +0.5 pp for Solis-60K-4G |
| Max DC voltage | 1100 V | 600 V | 500 V apart |
| Max efficiency | 99.0 % | 98.3 % | +0.7 pp for Solis-60K-4G |
| Max AC power | 66.00 kW | 57.70 kW | 8.30 kW apart |
| Max PV power | 72.00 kW | 100.97 kW | 28.97 kW apart |
| DC/AC ratio | 1.20 | 1.75 | +0.55 for SE100K (for 220V/230V line-to-line grids) |
| Nominal AC voltage | 400 V | 230 V | 170 V apart |
| Max AC current | 100.0 A | 145.0 A | 45.0 A apart |
| MPPT voltage range | 200-1000 V | 370-600 V | 200-1000 V vs 370-600 V |


## Every compared parameter


| Parameter | Solis-60K-4G | SE100K (for 220V/230V line-to-line grids) |
| --- | --- | --- |
| Rated AC power | 60.00 kW | 57.70 kW |
| Max AC power | 66.00 kW | 57.70 kW |
| Grid connection | 3-phase | 3-phase |
| Nominal AC voltage | 400 V | 230 V |
| Max AC current | 100.0 A | 145.0 A |
| Max PV power | 72.00 kW | 100.97 kW |
| DC/AC ratio | 1.20 | 1.75 |
| Max DC voltage | 1100 V | 600 V |
| MPPT voltage range | 200-1000 V | 370-600 V |
| Start voltage | 200 V | - |
| MPP trackers | 4 | - |
| Strings per tracker | 3 | - |
| Max input current per tracker | 28.5 A | - |
| European efficiency | 98.5 % | 98.0 % |
| Max efficiency | 99.0 % | 98.3 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | 63.0 kg | - |
| Weight per kW | 1.1 kg/kW | - |
| Dimensions | 700x630x357 mm | - |
| Ingress protection | IP65 | IP65 |
| Cooling | forced-air | forced-air |
| Noise | - | 67 dB |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | Yes | Yes |
| Ethernet | - | Yes |
| Arc fault protection | - | Yes |
| Integrated DC switch | - | Yes |
| Warranty | - | - |


## Related comparisons

- [Solis-60K-4G vs Huawei SUN2000-60KTL-M0](https://comparepv.com/compare-inverters/ginlong-solis-solis-60k-4g/huawei-sun2000-60ktl-m0) - 9 differences, the largest is max input current per tracker
- [Solis-60K-4G vs Sungrow SG60KTL-182](https://comparepv.com/compare-inverters/ginlong-solis-solis-60k-4g/sungrow-sg60ktl-182) - 10 differences, the largest is max dc voltage
- [Solis-60K-4G vs GoodWe GW60KN-MT](https://comparepv.com/compare-inverters/ginlong-solis-solis-60k-4g/goodwe-gw60kn-mt) - 6 differences, the largest is max input current per tracker


---

Source: https://comparepv.com/compare-inverters/ginlong-solis-solis-60k-4g/solaredge-se100k-for-220v-230v-line-to-line-grids

Not in this file, on the page: a written summary generated on request.