S6-GU3P350K06-EV-ND leads on the differences that matter

The largest is max input current per tracker: 20.0 A more headroom. 11 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Ginlong Solis S6-GU3P350K06-EV-ND](https://comparepv.com/inverter/ginlong-solis-s6-gu3p350k06-ev-nd) | [SOFAR 350KTLX0](https://comparepv.com/inverter/sofar-solar-sofar-350ktlx0) |
| Manufacturer | Ginlong Solis | Sofar Solar |
| Rated AC power | 350 kW | 350 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | S6-GU3P350K06-EV-ND | SOFAR 350KTLX0 | Difference |
| --- | --- | --- | --- |
| Max input current per tracker | 80.0 A | 60.0 A | +20.0 A for S6-GU3P350K06-EV-ND |
| Max AC power | 350.00 kW | 352.00 kW | 2.00 kW apart |
| Weight | 117.0 kg | 113.0 kg | -4.0 kg for SOFAR 350KTLX0 |
| Start voltage | 500 V | 550 V | -50 V for S6-GU3P350K06-EV-ND |
| Max AC current | 252.6 A | 254.1 A | 1.5 A apart |
| MPPT voltage range | 480-1500 V | 500-1500 V | 480-1500 V vs 500-1500 V |
| Strings per tracker | 5 | 4 | 1 string apart |
| Dimensions | 813x1098x378 mm | 828x1159x366 mm | 813x1098x378 mm vs 828x1159x366 mm |


## Every compared parameter


| Parameter | S6-GU3P350K06-EV-ND | SOFAR 350KTLX0 |
| --- | --- | --- |
| Rated AC power | 350.00 kW | 350.00 kW |
| Max AC power | 350.00 kW | 352.00 kW |
| Grid connection | 3-phase | 3-phase |
| Nominal AC voltage | 800 V | 800 V |
| Max AC current | 252.6 A | 254.1 A |
| Max PV power | - | - |
| DC/AC ratio | - | - |
| Max DC voltage | 1500 V | 1500 V |
| MPPT voltage range | 480-1500 V | 500-1500 V |
| Start voltage | 500 V | 550 V |
| MPP trackers | 6 | - |
| Strings per tracker | 5 | 4 |
| Max input current per tracker | 80.0 A | 60.0 A |
| European efficiency | 98.7 % | 98.8 % |
| Max efficiency | 99.0 % | 99.0 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | 117.0 kg | 113.0 kg |
| Weight per kW | 0.3 kg/kW | 0.3 kg/kW |
| Dimensions | 813x1098x378 mm | 828x1159x366 mm |
| Ingress protection | IP66 | IP66 |
| Cooling | forced-air | forced-air |
| Noise | - | - |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | - | - |
| Ethernet | - | - |
| Arc fault protection | - | - |
| Integrated DC switch | Yes | Yes |
| Warranty | - | - |


## Related comparisons

- [Ginlong Solis S6-GU3P350K06-EV-ND vs Sungrow SG350HX](https://comparepv.com/compare-inverters/ginlong-solis-s6-gu3p350k06-ev-nd/sungrow-sg350hx) - 9 differences, the largest is mpp trackers
- [Ginlong Solis S6-GU3P350K06-EV-ND vs Ginlong Solis S6-GU350K-EHV-M12](https://comparepv.com/compare-inverters/ginlong-solis-s6-gu3p350k06-ev-nd/ginlong-solis-s6-gu350k-ehv-m12) - 3 differences, the largest is weight
- [Ginlong Solis S6-GU3P350K06-EV-ND vs Ginlong Solis S6-GU350K-EHV-M16](https://comparepv.com/compare-inverters/ginlong-solis-s6-gu3p350k06-ev-nd/ginlong-solis-s6-gu350k-ehv-m16) - 3 differences, the largest is weight


---

Source: https://comparepv.com/compare-inverters/ginlong-solis-s6-gu3p350k06-ev-nd/sofar-solar-sofar-350ktlx0

Not in this file, on the page: a written summary generated on request.