# Ginlong Solis S6-GR1P3.6K-M vs Ginlong Solis S6-GR1P3.6K-S

9 differences, and they point both ways

The largest is max input current per tracker: 3.0 A more headroom. 14 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Ginlong Solis S6-GR1P3.6K-M](https://comparepv.com/inverter/ginlong-solis-s6-gr1p3-6k-m) | [Ginlong Solis S6-GR1P3.6K-S](https://comparepv.com/inverter/ginlong-solis-s6-gr1p3-6k-s) |
| Manufacturer | Ginlong Solis | Ginlong Solis |
| Rated AC power | 3.6 kW | 3.6 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | S6-GR1P3.6K-M | S6-GR1P3.6K-S | Difference |
| --- | --- | --- | --- |
| Max input current per tracker | 19.0 A | 16.0 A | +3.0 A for S6-GR1P3.6K-M |
| European efficiency | 96.8 % | 97.1 % | +0.3 pp for S6-GR1P3.6K-S |
| Max efficiency | 97.3 % | 97.6 % | +0.3 pp for S6-GR1P3.6K-S |
| MPP trackers | 1 | 2 | +1 trackers for S6-GR1P3.6K-S |
| Weight | 8.1 kg | 8.9 kg | -0.8 kg for S6-GR1P3.6K-M |
| Weight per kW | 2.2 kg/kW | 2.5 kg/kW | -0.2 kg/kW for S6-GR1P3.6K-M |
| MPPT voltage range | 50-500 V | 50-550 V | 50-500 V vs 50-550 V |
| Strings per tracker | 2 | 1 | 1 string apart |
| Dimensions | 373x310x160 mm | 371x330x161 mm | 373x310x160 mm vs 371x330x161 mm |


## Every compared parameter


| Parameter | S6-GR1P3.6K-M | S6-GR1P3.6K-S |
| --- | --- | --- |
| Rated AC power | 3.60 kW | 3.60 kW |
| Max AC power | 3.60 kW | 3.60 kW |
| Grid connection | Single-phase | Single-phase |
| Nominal AC voltage | 230 V | 230 V |
| Max AC current | 16.0 A | 16.0 A |
| Max PV power | 5.40 kW | 5.40 kW |
| DC/AC ratio | 1.50 | 1.50 |
| Max DC voltage | 550 V | 550 V |
| MPPT voltage range | 50-500 V | 50-550 V |
| Start voltage | 60 V | 60 V |
| MPP trackers | 1 | 2 |
| Strings per tracker | 2 | 1 |
| Max input current per tracker | 19.0 A | 16.0 A |
| European efficiency | 96.8 % | 97.1 % |
| Max efficiency | 97.3 % | 97.6 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | 8.1 kg | 8.9 kg |
| Weight per kW | 2.2 kg/kW | 2.5 kg/kW |
| Dimensions | 373x310x160 mm | 371x330x161 mm |
| Ingress protection | IP66 | IP66 |
| Cooling | natural | natural |
| Noise | 20 dB | 20 dB |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | Yes | - |
| Ethernet | - | - |
| Arc fault protection | Yes | - |
| Integrated DC switch | Yes | Yes |
| Warranty | - | - |


## Related comparisons

- [Ginlong Solis S6-GR1P3.6K-M vs SOFAR 3.6KTLM-G3](https://comparepv.com/compare-inverters/ginlong-solis-s6-gr1p3-6k-m/sofar-solar-sofar-3-6ktlm-g3) - 13 differences, the largest is european efficiency
- [Ginlong Solis S6-GR1P3.6K-M vs Growatt MIN 3600TL-X](https://comparepv.com/compare-inverters/ginlong-solis-s6-gr1p3-6k-m/growatt-min-3600tl-x) - 16 differences, the largest is max input current per tracker
- [Ginlong Solis S6-GR1P3.6K-M vs Ginlong Solis S6-GR1P3.6K](https://comparepv.com/compare-inverters/ginlong-solis-s6-gr1p3-6k-m/ginlong-solis-s6-gr1p3-6k) - 10 differences, the largest is max dc voltage


---

Source: https://comparepv.com/compare-inverters/ginlong-solis-s6-gr1p3-6k-m/ginlong-solis-s6-gr1p3-6k-s

Not in this file, on the page: a written summary generated on request.