title: "Ginlong Solis S6-GC3P23K03-LV-ND vs GoodWe GW23K-SDT-CN-G40 - Inverter Comparison | ComparePV"
description: "Compare Ginlong Solis S6-GC3P23K03-LV-ND vs GoodWe GW23K-SDT-CN-G40 side by side: what actually differs, efficiency, MPP trackers, battery input and the full specification."
source: "https://comparepv.com/compare-inverters/ginlong-solis-s6-gc3p23k03-lv-nd/goodwe-gw23k-sdt-cn-g40"
updated: 2026-01-17
---

# Ginlong Solis S6-GC3P23K03-LV-ND vs GoodWe GW23K-SDT-CN-G40

GW23K-SDT-CN-G40 leads on the differences that matter

The largest is max input current per tracker: 19.0 A more headroom. 8 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Ginlong Solis S6-GC3P23K03-LV-ND](https://comparepv.com/inverter/ginlong-solis-s6-gc3p23k03-lv-nd) | [GoodWe GW23K-SDT-CN-G40](https://comparepv.com/inverter/goodwe-gw23k-sdt-cn-g40) |
| Manufacturer | Ginlong Solis | GoodWe |
| Rated AC power | 23 kW | 23 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | S6-GC3P23K03-LV-ND | GW23K-SDT-CN-G40 | Difference |
| --- | --- | --- | --- |
| Max input current per tracker | 40.0 A | 21.0 A | +19.0 A for S6-GC3P23K03-LV-ND |
| Max efficiency | 97.8 % | 98.7 % | +0.9 pp for GW23K-SDT-CN-G40 |
| Max AC power | 23.00 kW | 25.30 kW | 2.30 kW apart |
| Weight | 32.6 kg | 17.0 kg | -15.6 kg for GW23K-SDT-CN-G40 |
| Noise | 60 dB | 45 dB | -15 dB for GW23K-SDT-CN-G40 |
| Weight per kW | 1.4 kg/kW | 0.7 kg/kW | -0.7 kg/kW for GW23K-SDT-CN-G40 |
| Nominal AC voltage | 230 V | 380 V | 150 V apart |
| Max AC current | 60.4 A | 38.4 A | 22.0 A apart |
| MPPT voltage range | 180-1000 V | 140-1000 V | 180-1000 V vs 140-1000 V |
| Start voltage | 180 V | 160 V | -20 V for GW23K-SDT-CN-G40 |
| Dimensions | 672x515x288 mm | 413x530x211 mm | 672x515x288 mm vs 413x530x211 mm |


## Every compared parameter


| Parameter | S6-GC3P23K03-LV-ND | GW23K-SDT-CN-G40 |
| --- | --- | --- |
| Rated AC power | 23.00 kW | 23.00 kW |
| Max AC power | 23.00 kW | 25.30 kW |
| Grid connection | 3-phase | 3-phase |
| Nominal AC voltage | 230 V | 380 V |
| Max AC current | 60.4 A | 38.4 A |
| Max PV power | - | - |
| DC/AC ratio | - | - |
| Max DC voltage | 1100 V | 1100 V |
| MPPT voltage range | 180-1000 V | 140-1000 V |
| Start voltage | 180 V | 160 V |
| MPP trackers | - | 2 |
| Strings per tracker | 2 | 2 |
| Max input current per tracker | 40.0 A | 21.0 A |
| European efficiency | 97.3 % | - |
| Max efficiency | 97.8 % | 98.7 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | 32.6 kg | 17.0 kg |
| Weight per kW | 1.4 kg/kW | 0.7 kg/kW |
| Dimensions | 672x515x288 mm | 413x530x211 mm |
| Ingress protection | IP66 | IP66 |
| Cooling | forced-air | forced-air |
| Noise | 60 dB | 45 dB |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | - | - |
| Ethernet | - | - |
| Arc fault protection | - | - |
| Integrated DC switch | Yes | Yes |
| Warranty | - | - |


## Related comparisons

- [Ginlong Solis S6-GC3P23K03-LV-ND vs Sungrow SG23T-P2-CN](https://comparepv.com/compare-inverters/ginlong-solis-s6-gc3p23k03-lv-nd/sungrow-sg23t-p2-cn) - 10 differences, the largest is european efficiency
- [Ginlong Solis S6-GC3P23K03-LV-ND vs SOFAR 23KTLX-G3P](https://comparepv.com/compare-inverters/ginlong-solis-s6-gc3p23k03-lv-nd/sofar-solar-sofar-23ktlx-g3p) - 7 differences, the largest is european efficiency
- [Ginlong Solis S6-GC3P23K03-LV-ND vs Ginlong Solis S5-GC23K-LV](https://comparepv.com/compare-inverters/ginlong-solis-s6-gc3p23k03-lv-nd/ginlong-solis-s5-gc23k-lv) - 6 differences, the largest is max input current per tracker


---

Source: https://comparepv.com/compare-inverters/ginlong-solis-s6-gc3p23k03-lv-nd/goodwe-gw23k-sdt-cn-g40

Not in this file, on the page: a written summary generated on request.