# Ginlong Solis S6-GC100K vs Huawei SUN2000-100KTL-M1 (@480 V)

7 differences, and they point both ways

The largest is max input current per tracker: 16.0 A more headroom. 13 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Ginlong Solis S6-GC100K](https://comparepv.com/inverter/ginlong-solis-s6-gc100k) | [Huawei SUN2000-100KTL-M1 (@480 V)](https://comparepv.com/inverter/huawei-sun2000-100ktl-m1-480-v) |
| Manufacturer | Ginlong Solis | Huawei |
| Rated AC power | 100 kW | 100 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | S6-GC100K | SUN2000-100KTL-M1 (@480 V) | Difference |
| --- | --- | --- | --- |
| Max input current per tracker | 42.0 A | 26.0 A | +16.0 A for S6-GC100K |
| Weight | 96.0 kg | 90.0 kg | -6.0 kg for SUN2000-100KTL-M1 (@480 V) |
| European efficiency | 98.3 % | 98.6 % | +0.3 pp for SUN2000-100KTL-M1 (@480 V) |
| Max AC current | 167.1 A | 133.7 A | 33.4 A apart |
| MPPT voltage range | 160-1000 V | 200-1000 V | 160-1000 V vs 200-1000 V |
| Start voltage | 180 V | 200 V | -20 V for S6-GC100K |
| Dimensions | 567x1014x345 mm | 700x1035x365 mm | 567x1014x345 mm vs 700x1035x365 mm |


## Every compared parameter


| Parameter | S6-GC100K | SUN2000-100KTL-M1 (@480 V) |
| --- | --- | --- |
| Rated AC power | 100.00 kW | 100.00 kW |
| Max AC power | 110.00 kW | 110.00 kW |
| Grid connection | 3-phase | 3-phase |
| Nominal AC voltage | 400 V | - |
| Max AC current | 167.1 A | 133.7 A |
| Max PV power | - | - |
| DC/AC ratio | - | - |
| Max DC voltage | 1100 V | 1100 V |
| MPPT voltage range | 160-1000 V | 200-1000 V |
| Start voltage | 180 V | 200 V |
| MPP trackers | 10 | 10 |
| Strings per tracker | 2 | 2 |
| Max input current per tracker | 42.0 A | 26.0 A |
| European efficiency | 98.3 % | 98.6 % |
| Max efficiency | 98.7 % | 98.8 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | 96.0 kg | 90.0 kg |
| Weight per kW | 1.0 kg/kW | 0.9 kg/kW |
| Dimensions | 567x1014x345 mm | 700x1035x365 mm |
| Ingress protection | IP66 | IP66 |
| Cooling | forced-air | forced-air |
| Noise | - | - |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | Yes | Yes |
| Ethernet | - | - |
| Arc fault protection | Yes | - |
| Integrated DC switch | Yes | Yes |
| Warranty | - | - |


## Related comparisons

- [Ginlong Solis S6-GC100K vs Huawei SUN2000-100KTL-M2](https://comparepv.com/compare-inverters/ginlong-solis-s6-gc100k/huawei-sun2000-100ktl-m2) - 7 differences, the largest is max input current per tracker
- [Ginlong Solis S6-GC100K vs Sungrow SG110CX](https://comparepv.com/compare-inverters/ginlong-solis-s6-gc100k/sungrow-sg110cx) - 8 differences, the largest is max input current per tracker
- [Ginlong Solis S6-GC100K vs SMA Solar Sunny Highpower PEAK3 SHP 100-21](https://comparepv.com/compare-inverters/ginlong-solis-s6-gc100k/sma-solar-sunny-highpower-peak3-shp-100-21) - 9 differences, the largest is mpp trackers
- [Huawei SUN2000-100KTL-M1 (@480 V) vs SMA Solar Sunny Highpower Storage SHPS 100-21](https://comparepv.com/compare-inverters/huawei-sun2000-100ktl-m1-480-v/sma-solar-sunny-highpower-storage-shps-100-21) - 6 differences, the largest is max dc voltage


---

Source: https://comparepv.com/compare-inverters/ginlong-solis-s6-gc100k/huawei-sun2000-100ktl-m1-480-v

Not in this file, on the page: a written summary generated on request.