title: "Ginlong Solis S5-GC50K vs Growatt MAX 50KTL3 LV - Inverter Comparison | ComparePV"
description: "Compare Ginlong Solis S5-GC50K vs Growatt MAX 50KTL3 LV side by side: what actually differs, efficiency, MPP trackers, battery input and the full specification."
source: "https://comparepv.com/compare-inverters/ginlong-solis-s5-gc50k/growatt-max-50ktl3-lv"
updated: 2026-01-17
---

# Ginlong Solis S5-GC50K vs Growatt MAX 50KTL3 LV

S5-GC50K leads on the differences that matter

The largest is max input current per tracker: 6.0 A more headroom. 11 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Ginlong Solis S5-GC50K](https://comparepv.com/inverter/ginlong-solis-s5-gc50k) | [Growatt MAX 50KTL3 LV](https://comparepv.com/inverter/growatt-max-50ktl3-lv) |
| Manufacturer | Ginlong Solis | Growatt |
| Rated AC power | 50 kW | 50 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | S5-GC50K | MAX 50KTL3 LV | Difference |
| --- | --- | --- | --- |
| Max input current per tracker | 32.0 A | 26.0 A | +6.0 A for S5-GC50K |
| Max AC power | 55.00 kW | 55.50 kW | 0.50 kW apart |
| Weight | 53.7 kg | 82.0 kg | -28.3 kg for S5-GC50K |
| Weight per kW | 1.1 kg/kW | 1.6 kg/kW | -0.6 kg/kW for S5-GC50K |
| Max AC current | 83.6 A | 80.5 A | 3.1 A apart |
| Start voltage | 195 V | 250 V | -55 V for S5-GC50K |
| Ingress protection | IP66 | IP65 | IP66 vs IP65 |
| MPPT voltage range | 180-1000 V | 200-1000 V | 180-1000 V vs 200-1000 V |
| Dimensions | 578x691x338 mm | 600x860x300 mm | 578x691x338 mm vs 600x860x300 mm |


## Every compared parameter


| Parameter | S5-GC50K | MAX 50KTL3 LV |
| --- | --- | --- |
| Rated AC power | 50.00 kW | 50.00 kW |
| Max AC power | 55.00 kW | 55.50 kW |
| Grid connection | 3-phase | 3-phase |
| Nominal AC voltage | 400 V | 400 V |
| Max AC current | 83.6 A | 80.5 A |
| Max PV power | - | 75.00 kW |
| DC/AC ratio | - | 1.50 |
| Max DC voltage | 1100 V | 1100 V |
| MPPT voltage range | 180-1000 V | 200-1000 V |
| Start voltage | 195 V | 250 V |
| MPP trackers | - | - |
| Strings per tracker | 2 | 2 |
| Max input current per tracker | 32.0 A | 26.0 A |
| European efficiency | 98.3 % | 98.4 % |
| Max efficiency | 98.7 % | 98.8 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | 53.7 kg | 82.0 kg |
| Weight per kW | 1.1 kg/kW | 1.6 kg/kW |
| Dimensions | 578x691x338 mm | 600x860x300 mm |
| Ingress protection | IP66 | IP65 |
| Cooling | forced-air | forced-air |
| Noise | 55 dB | - |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | Yes | Yes |
| Ethernet | - | - |
| Arc fault protection | - | - |
| Integrated DC switch | Yes | Yes |
| Warranty | - | 5 yrs |


## Related comparisons

- [Ginlong Solis S5-GC50K vs Huawei SUN2000-50KTL-JPM0](https://comparepv.com/compare-inverters/ginlong-solis-s5-gc50k/huawei-sun2000-50ktl-jpm0) - 11 differences, the largest is max input current per tracker
- [Ginlong Solis S5-GC50K vs Huawei SUN2000-50KTL-M0](https://comparepv.com/compare-inverters/ginlong-solis-s5-gc50k/huawei-sun2000-50ktl-m0) - 9 differences, the largest is max input current per tracker
- [Ginlong Solis S5-GC50K vs Solis-50K-HV](https://comparepv.com/compare-inverters/ginlong-solis-s5-gc50k/ginlong-solis-solis-50k-hv) - 7 differences, the largest is weight
- [Growatt MAX 50KTL3 LV vs Sungrow SG50CX](https://comparepv.com/compare-inverters/growatt-max-50ktl3-lv/sungrow-sg50cx) - 6 differences, the largest is max ac power


---

Source: https://comparepv.com/compare-inverters/ginlong-solis-s5-gc50k/growatt-max-50ktl3-lv

Not in this file, on the page: a written summary generated on request.