# Ginlong Solis S5-GC36K vs GoodWe GW36K-MT

8 differences, and they point both ways

The largest is max input current per tracker: 2.0 A more headroom. 12 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Ginlong Solis S5-GC36K](https://comparepv.com/inverter/ginlong-solis-s5-gc36k) | [GoodWe GW36K-MT](https://comparepv.com/inverter/goodwe-gw36k-mt) |
| Manufacturer | Ginlong Solis | GoodWe |
| Rated AC power | 36 kW | 36 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | S5-GC36K | GW36K-MT | Difference |
| --- | --- | --- | --- |
| Max input current per tracker | 32.0 A | 30.0 A | +2.0 A for S5-GC36K |
| Max AC power | 39.60 kW | 36.00 kW | 3.60 kW apart |
| Weight | 42.1 kg | 40.0 kg | -2.1 kg for GW36K-MT |
| European efficiency | 98.3 % | 98.5 % | +0.2 pp for GW36K-MT |
| Max AC current | 60.2 A | 53.3 A | 6.9 A apart |
| Ingress protection | IP66 | IP65 | IP66 vs IP65 |
| MPPT voltage range | 200-1000 V | 200-950 V | 200-1000 V vs 200-950 V |
| Dimensions | 629x647x252 mm | 590x480x200 mm | 629x647x252 mm vs 590x480x200 mm |


## Every compared parameter


| Parameter | S5-GC36K | GW36K-MT |
| --- | --- | --- |
| Rated AC power | 36.00 kW | 36.00 kW |
| Max AC power | 39.60 kW | 36.00 kW |
| Grid connection | 3-phase | 3-phase |
| Nominal AC voltage | 400 V | 400 V |
| Max AC current | 60.2 A | 53.3 A |
| Max PV power | 54.00 kW | - |
| DC/AC ratio | 1.50 | - |
| Max DC voltage | 1100 V | 1100 V |
| MPPT voltage range | 200-1000 V | 200-950 V |
| Start voltage | 180 V | 180 V |
| MPP trackers | - | - |
| Strings per tracker | 2 | 2 |
| Max input current per tracker | 32.0 A | 30.0 A |
| European efficiency | 98.3 % | 98.5 % |
| Max efficiency | 98.7 % | 98.8 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | 42.1 kg | 40.0 kg |
| Weight per kW | 1.2 kg/kW | 1.1 kg/kW |
| Dimensions | 629x647x252 mm | 590x480x200 mm |
| Ingress protection | IP66 | IP65 |
| Cooling | forced-air | forced-air |
| Noise | 60 dB | - |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | Yes | Yes |
| Ethernet | - | - |
| Arc fault protection | - | - |
| Integrated DC switch | Yes | Yes |
| Warranty | - | - |


## Related comparisons

- [Ginlong Solis S5-GC36K vs Growatt MID 36KTL3-X](https://comparepv.com/compare-inverters/ginlong-solis-s5-gc36k/growatt-mid-36ktl3-x) - 6 differences, the largest is max input current per tracker
- [Ginlong Solis S5-GC36K vs Huawei SUN2000-36KTL](https://comparepv.com/compare-inverters/ginlong-solis-s5-gc36k/huawei-sun2000-36ktl) - 9 differences, the largest is max input current per tracker
- [Ginlong Solis S5-GC36K vs Huawei SUN2000-36KTL-M3](https://comparepv.com/compare-inverters/ginlong-solis-s5-gc36k/huawei-sun2000-36ktl-m3) - 7 differences, the largest is max input current per tracker
- [GoodWe GW36K-MT vs Sungrow SG36CX-P2](https://comparepv.com/compare-inverters/goodwe-gw36k-mt/sungrow-sg36cx-p2) - 8 differences, the largest is max ac power


---

Source: https://comparepv.com/compare-inverters/ginlong-solis-s5-gc36k/goodwe-gw36k-mt

Not in this file, on the page: a written summary generated on request.