# Ginlong Solis S5-GC23K-LV vs Ginlong Solis S6-GC3P23K03-LV-ND

S6-GC3P23K03-LV-ND leads on the differences that matter

The largest is max input current per tracker: 8.0 A more headroom. 12 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Ginlong Solis S5-GC23K-LV](https://comparepv.com/inverter/ginlong-solis-s5-gc23k-lv) | [Ginlong Solis S6-GC3P23K03-LV-ND](https://comparepv.com/inverter/ginlong-solis-s6-gc3p23k03-lv-nd) |
| Manufacturer | Ginlong Solis | Ginlong Solis |
| Rated AC power | 23 kW | 23 kW |
| Type | Grid-tie | Grid-tie |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | S5-GC23K-LV | S6-GC3P23K03-LV-ND | Difference |
| --- | --- | --- | --- |
| Max input current per tracker | 32.0 A | 40.0 A | +8.0 A for S6-GC3P23K03-LV-ND |
| Max AC power | 25.00 kW | 23.00 kW | 2.00 kW apart |
| Max AC current | 65.0 A | 60.4 A | 4.6 A apart |
| Nominal AC voltage | 220 V | 230 V | 10 V apart |
| MPPT voltage range | 200-1000 V | 180-1000 V | 200-1000 V vs 180-1000 V |
| Dimensions | 629x647x252 mm | 672x515x288 mm | 629x647x252 mm vs 672x515x288 mm |


## Every compared parameter


| Parameter | S5-GC23K-LV | S6-GC3P23K03-LV-ND |
| --- | --- | --- |
| Rated AC power | 23.00 kW | 23.00 kW |
| Max AC power | 25.00 kW | 23.00 kW |
| Grid connection | 3-phase | 3-phase |
| Nominal AC voltage | 220 V | 230 V |
| Max AC current | 65.0 A | 60.4 A |
| Max PV power | 34.50 kW | - |
| DC/AC ratio | 1.50 | - |
| Max DC voltage | 1100 V | 1100 V |
| MPPT voltage range | 200-1000 V | 180-1000 V |
| Start voltage | 180 V | 180 V |
| MPP trackers | 3 | - |
| Strings per tracker | 2 | 2 |
| Max input current per tracker | 32.0 A | 40.0 A |
| European efficiency | 97.3 % | 97.3 % |
| Max efficiency | 97.8 % | 97.8 % |
| CEC efficiency | - | - |
| Battery input | - | - |
| Battery voltage | - | - |
| Max charge current | - | - |
| Backup power | - | - |
| Weight | - | 32.6 kg |
| Weight per kW | - | 1.4 kg/kW |
| Dimensions | 629x647x252 mm | 672x515x288 mm |
| Ingress protection | IP66 | IP66 |
| Cooling | forced-air | forced-air |
| Noise | 60 dB | 60 dB |
| Max operating temperature | 60 °C | 60 °C |
| Wi-Fi | Yes | - |
| Ethernet | - | - |
| Arc fault protection | Yes | - |
| Integrated DC switch | Yes | Yes |
| Warranty | - | - |


## Related comparisons

- [Ginlong Solis S5-GC23K-LV vs Sungrow SG23T-P2-CN](https://comparepv.com/compare-inverters/ginlong-solis-s5-gc23k-lv/sungrow-sg23t-p2-cn) - 10 differences, the largest is european efficiency
- [Ginlong Solis S5-GC23K-LV vs SOFAR 23KTLX-G3P](https://comparepv.com/compare-inverters/ginlong-solis-s5-gc23k-lv/sofar-solar-sofar-23ktlx-g3p) - 8 differences, the largest is european efficiency
- [Ginlong Solis S5-GC23K-LV vs GoodWe GW23K-SDT-CN-G40](https://comparepv.com/compare-inverters/ginlong-solis-s5-gc23k-lv/goodwe-gw23k-sdt-cn-g40) - 10 differences, the largest is max input current per tracker


---

Source: https://comparepv.com/compare-inverters/ginlong-solis-s5-gc23k-lv/ginlong-solis-s6-gc3p23k03-lv-nd