# Easun Power ISolar SMV IV 3600-24 vs Easun Power LSOLAR SML-II-3.6KW

ISolar SMV IV 3600-24 leads on the differences that matter

The largest is max pv power: 1.00 kW apart. 2 of 7 comparable parameters are identical, with 25 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Easun Power ISolar SMV IV 3600-24](https://comparepv.com/inverter/easun-power-isolar-smv-iv-3600-24) | [Easun Power LSOLAR SML-II-3.6KW](https://comparepv.com/inverter/easun-power-lsolar-sml-ii-3-6kw) |
| Manufacturer | Easun Power | Easun Power |
| Rated AC power | 3.6 kW | 3.6 kW |
| Type | Off-grid | Off-grid |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | ISolar SMV IV 3600-24 | LSOLAR SML-II-3.6KW | Difference |
| --- | --- | --- | --- |
| Max PV power | 4.00 kW | 5.00 kW | 1.00 kW apart |
| DC/AC ratio | 1.11 | 1.39 | +0.28 for LSOLAR SML-II-3.6KW |
| Weight | 9.0 kg | 11.0 kg | -2.0 kg for ISolar SMV IV 3600-24 |
| Weight per kW | 2.5 kg/kW | 3.1 kg/kW | -0.6 kg/kW for ISolar SMV IV 3600-24 |
| Dimensions | 115x300x400 mm | 300x100x440 mm | 115x300x400 mm vs 300x100x440 mm |


## Every compared parameter


| Parameter | ISolar SMV IV 3600-24 | LSOLAR SML-II-3.6KW |
| --- | --- | --- |
| Rated AC power | 3.60 kW | 3.60 kW |
| Max AC power | 3.60 kW | 3.60 kW |
| Grid connection | - | Single-phase |
| Nominal AC voltage | - | 230 V |
| Max AC current | - | - |
| Max PV power | 4.00 kW | 5.00 kW |
| DC/AC ratio | 1.11 | 1.39 |
| Max DC voltage | - | 500 V |
| MPPT voltage range | - | 120-450 V |
| Start voltage | - | - |
| MPP trackers | - | 1 |
| Strings per tracker | - | - |
| Max input current per tracker | - | 100.0 A |
| European efficiency | - | - |
| Max efficiency | - | 98.0 % |
| CEC efficiency | - | - |
| Battery input | - | Yes |
| Battery voltage | - | - |
| Max charge current | - | 100 A |
| Backup power | - | - |
| Weight | 9.0 kg | 11.0 kg |
| Weight per kW | 2.5 kg/kW | 3.1 kg/kW |
| Dimensions | 115x300x400 mm | 300x100x440 mm |
| Ingress protection | - | IP21 |
| Cooling | forced-air | - |
| Noise | 60 dB | - |
| Max operating temperature | - | 55 °C |
| Wi-Fi | - | Yes |
| Ethernet | - | - |
| Arc fault protection | - | - |
| Integrated DC switch | - | - |
| Warranty | - | 1 yrs |


## Related comparisons

- [Easun Power ISolar SMV IV 3600-24 vs Easun Power ISolar SMG II 3.6KW](https://comparepv.com/compare-inverters/easun-power-isolar-smv-iv-3600-24/easun-power-isolar-smg-ii-3-6kw) - One difference: dimensions
- [Easun Power ISolar SMV IV 3600-24 vs Easun Power ISolar-SMX-II-3.6KW](https://comparepv.com/compare-inverters/easun-power-isolar-smv-iv-3600-24/easun-power-isolar-smx-ii-3-6kw) - 3 differences, the largest is weight
- [Easun Power ISolar SMV IV 3600-24 vs Growatt SPF 3500 ES](https://comparepv.com/compare-inverters/easun-power-isolar-smv-iv-3600-24/growatt-spf-3500-es) - 7 differences, the largest is rated ac power


---

Source: https://comparepv.com/compare-inverters/easun-power-isolar-smv-iv-3600-24/easun-power-lsolar-sml-ii-3-6kw