title: "Easun Power ISolar MLV 6KW vs Growatt SPF 6000 ES Plus - Inverter Comparison | ComparePV"
description: "Compare Easun Power ISolar MLV 6KW vs Growatt SPF 6000 ES Plus side by side: what actually differs, efficiency, MPP trackers, battery input and the full specification."
source: "https://comparepv.com/compare-inverters/easun-power-isolar-mlv-6kw/growatt-spf-6000-es-plus"
updated: 2026-01-19
---

# Easun Power ISolar MLV 6KW vs Growatt SPF 6000 ES Plus

4 differences, and they point both ways

The largest is max efficiency: 3.0 pp more efficient. 4 of 8 comparable parameters are identical, with 24 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Easun Power ISolar MLV 6KW](https://comparepv.com/inverter/easun-power-isolar-mlv-6kw) | [Growatt SPF 6000 ES Plus](https://comparepv.com/inverter/growatt-spf-6000-es-plus) |
| Manufacturer | Easun Power | Growatt |
| Rated AC power | 6 kW | 6 kW |
| Type | Off-grid | Off-grid |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | ISolar MLV 6KW | SPF 6000 ES Plus | Difference |
| --- | --- | --- | --- |
| Max efficiency | 96.0 % | 93.0 % | +3.0 pp for ISolar MLV 6KW |
| Weight | 30.0 kg | 13.5 kg | -16.5 kg for SPF 6000 ES Plus |
| Weight per kW | 5.0 kg/kW | 2.2 kg/kW | -2.8 kg/kW for SPF 6000 ES Plus |
| Dimensions | 610x623x610 mm | 395x460x132 mm | 610x623x610 mm vs 395x460x132 mm |


## Every compared parameter


| Parameter | ISolar MLV 6KW | SPF 6000 ES Plus |
| --- | --- | --- |
| Rated AC power | 6.00 kW | 6.00 kW |
| Max AC power | 6.00 kW | 6.00 kW |
| Grid connection | - | Single-phase |
| Nominal AC voltage | - | 230 V |
| Max AC current | - | - |
| Max PV power | 8.00 kW | 8.00 kW |
| DC/AC ratio | 1.33 | 1.33 |
| Max DC voltage | - | 500 V |
| MPPT voltage range | - | 120-450 V |
| Start voltage | - | - |
| MPP trackers | - | 2 |
| Strings per tracker | - | 1 |
| Max input current per tracker | - | 16.0 A |
| European efficiency | - | - |
| Max efficiency | 96.0 % | 93.0 % |
| CEC efficiency | - | - |
| Battery input | - | Yes |
| Battery voltage | - | 48VDC |
| Max charge current | - | 80 A |
| Backup power | - | 6.0 kW |
| Weight | 30.0 kg | 13.5 kg |
| Weight per kW | 5.0 kg/kW | 2.2 kg/kW |
| Dimensions | 610x623x610 mm | 395x460x132 mm |
| Ingress protection | - | IP20 |
| Cooling | forced-air | - |
| Noise | 60 dB | - |
| Max operating temperature | - | 55 °C |
| Wi-Fi | - | - |
| Ethernet | - | - |
| Arc fault protection | - | - |
| Integrated DC switch | - | - |
| Warranty | - | - |


## Related comparisons

- [Easun Power ISolar MLV 6KW vs Growatt SPF 6000T DVM](https://comparepv.com/compare-inverters/easun-power-isolar-mlv-6kw/growatt-spf-6000t-dvm) - 4 differences, the largest is max efficiency
- [Easun Power ISolar MLV 6KW vs Growatt SPF 6000T DVM-MPV](https://comparepv.com/compare-inverters/easun-power-isolar-mlv-6kw/growatt-spf-6000t-dvm-mpv) - 6 differences, the largest is max efficiency
- [Easun Power ISolar MLV 6KW vs Growatt SPF 6000T DVM-G2](https://comparepv.com/compare-inverters/easun-power-isolar-mlv-6kw/growatt-spf-6000t-dvm-g2) - 6 differences, the largest is max efficiency
- [Growatt SPF 6000 ES Plus vs SMA Solar SI8.0H-13](https://comparepv.com/compare-inverters/growatt-spf-6000-es-plus/sma-solar-si8-0h-13) - 10 differences, the largest is max dc voltage


---

Source: https://comparepv.com/compare-inverters/easun-power-isolar-mlv-6kw/growatt-spf-6000-es-plus

Not in this file, on the page: a written summary generated on request.