title: "Easun Power 6.2KVA (PVmax=500V, 48V battery) vs Easun Power 6.2KW - Inverter Comparison | ComparePV"
description: "Compare Easun Power 6.2KVA (PVmax=500V, 48V battery) vs Easun Power 6.2KW side by side: what actually differs, efficiency, MPP trackers, battery input and the full specification."
source: "https://comparepv.com/compare-inverters/easun-power-6-2kva-pvmax-500v-48v-battery/easun-power-6-2kw"
updated: 2026-01-19
---

# Easun Power 6.2KVA (PVmax=500V, 48V battery) vs Easun Power 6.2KW

2KVA (PVmax=500V, 48V battery) leads on the differences that matter

The largest is max efficiency: 1.0 pp more efficient. 13 of 17 comparable parameters are identical, with 15 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Easun Power 6.2KVA (PVmax=500V, 48V battery)](https://comparepv.com/inverter/easun-power-6-2kva-pvmax-500v-48v-battery) | [Easun Power 6.2KW](https://comparepv.com/inverter/easun-power-6-2kw) |
| Manufacturer | Easun Power | Easun Power |
| Rated AC power | 6.2 kW | 6.2 kW |
| Type | Hybrid | Hybrid |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | 2KVA (PVmax=500V, 48V battery) | 2KW | Difference |
| --- | --- | --- | --- |
| Max efficiency | 94.0 % | 93.0 % | +1.0 pp for 2KVA (PVmax=500V, 48V battery) |
| Max operating temperature | 55 °C | 50 °C | +5 °C for 2KVA (PVmax=500V, 48V battery) |
| Battery voltage | Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) | 24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW) | Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) vs 24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW) |
| Dimensions | 105x295x438 mm | 442x358x116 mm | 105x295x438 mm vs 442x358x116 mm |


## Every compared parameter


| Parameter | 2KVA (PVmax=500V, 48V battery) | 2KW |
| --- | --- | --- |
| Rated AC power | 6.20 kW | 6.20 kW |
| Max AC power | 6.20 kW | 6.20 kW |
| Grid connection | Single-phase | Single-phase |
| Nominal AC voltage | 230 V | 230 V |
| Max AC current | - | 26.9 A |
| Max PV power | 6.50 kW | 6.50 kW |
| DC/AC ratio | 1.05 | 1.05 |
| Max DC voltage | 500 V | 500 V |
| MPPT voltage range | 60-500 V | 60-500 V |
| Start voltage | - | - |
| MPP trackers | - | - |
| Strings per tracker | - | - |
| Max input current per tracker | - | - |
| European efficiency | - | - |
| Max efficiency | 94.0 % | 93.0 % |
| CEC efficiency | - | - |
| Battery input | Yes | Yes |
| Battery voltage | Nominal DC input: 12 Vdc (2KVA), 24 Vdc (4KVA PVmax=160V), 48 Vdc (4KVA/5.5KVA/6.2KVA) | 24 Vdc (3.6/4.2 kW) or 48 Vdc (6.2 kW) |
| Max charge current | 120 A | 120 A |
| Backup power | - | - |
| Weight | 8.7 kg | 8.9 kg |
| Weight per kW | 1.4 kg/kW | 1.4 kg/kW |
| Dimensions | 105x295x438 mm | 442x358x116 mm |
| Ingress protection | - | - |
| Cooling | forced-air | forced-air |
| Noise | - | - |
| Max operating temperature | 55 °C | 50 °C |
| Wi-Fi | - | Yes |
| Ethernet | - | - |
| Arc fault protection | - | - |
| Integrated DC switch | - | - |
| Warranty | - | - |


## Related comparisons

- [Easun Power 6.2KVA (PVmax=500V, 48V battery) vs Easun Power POW-HVM6200W-48V](https://comparepv.com/compare-inverters/easun-power-6-2kva-pvmax-500v-48v-battery/easun-power-pow-hvm6200w-48v) - One difference: dimensions
- [Easun Power 6.2KVA (PVmax=500V, 48V battery) vs Easun Power 6.2KVA (48V)](https://comparepv.com/compare-inverters/easun-power-6-2kva-pvmax-500v-48v-battery/easun-power-6-2kva-48v) - 3 differences, the largest is weight
- [Easun Power 6.2KVA (PVmax=500V, 48V battery) vs Easun Power POW-HVM6.2K-PRO (6.2KW)](https://comparepv.com/compare-inverters/easun-power-6-2kva-pvmax-500v-48v-battery/easun-power-pow-hvm6-2k-pro-6-2kw) - 9 differences, the largest is max efficiency


---

Source: https://comparepv.com/compare-inverters/easun-power-6-2kva-pvmax-500v-48v-battery/easun-power-6-2kw

Not in this file, on the page: a written summary generated on request.