title: "Easun Power 6.2KVA (48V) vs Easun Power POW-HVM6.2KP - Inverter Comparison | ComparePV"
description: "Compare Easun Power 6.2KVA (48V) vs Easun Power POW-HVM6.2KP side by side: what actually differs, efficiency, MPP trackers, battery input and the full specification."
source: "https://comparepv.com/compare-inverters/easun-power-6-2kva-48v/easun-power-pow-hvm6-2kp"
updated: 2026-01-19
---

# Easun Power 6.2KVA (48V) vs Easun Power POW-HVM6.2KP

POW-HVM6.2KP leads on the differences that matter

The largest is max efficiency: 4.0 pp more efficient. 12 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.


## The two inverters


| Attribute | A | B |
| --- | --- | --- |
| Inverter | [Easun Power 6.2KVA (48V)](https://comparepv.com/inverter/easun-power-6-2kva-48v) | [Easun Power POW-HVM6.2KP](https://comparepv.com/inverter/easun-power-pow-hvm6-2kp) |
| Manufacturer | Easun Power | Easun Power |
| Rated AC power | 6.2 kW | 6.2 kW |
| Type | Hybrid | Hybrid |


## Where they differ

Ranked by how much the difference matters, not by datasheet order.


| Parameter | 6.2KVA (48V) | POW-HVM6.2KP | Difference |
| --- | --- | --- | --- |
| Max efficiency | 94.0 % | 98.0 % | +4.0 pp for POW-HVM6.2KP |
| Max AC power | 6.20 kW | 6.50 kW | 0.30 kW apart |
| Max PV power | 6.50 kW | 8.50 kW | 2.00 kW apart |
| DC/AC ratio | 1.05 | 1.37 | +0.32 for POW-HVM6.2KP |
| Max operating temperature | 55 °C | 50 °C | +5 °C for 6.2KVA (48V) |
| Weight | 10.0 kg | 10.7 kg | -0.7 kg for 6.2KVA (48V) |


## Every compared parameter


| Parameter | 6.2KVA (48V) | POW-HVM6.2KP |
| --- | --- | --- |
| Rated AC power | 6.20 kW | 6.20 kW |
| Max AC power | 6.20 kW | 6.50 kW |
| Grid connection | Single-phase | Single-phase |
| Nominal AC voltage | 230 V | 230 V |
| Max AC current | - | 26.9 A |
| Max PV power | 6.50 kW | 8.50 kW |
| DC/AC ratio | 1.05 | 1.37 |
| Max DC voltage | 500 V | 500 V |
| MPPT voltage range | 60-500 V | 60-500 V |
| Start voltage | - | - |
| MPP trackers | 1 | 1 |
| Strings per tracker | - | - |
| Max input current per tracker | 27.0 A | 27.0 A |
| European efficiency | - | - |
| Max efficiency | 94.0 % | 98.0 % |
| CEC efficiency | - | - |
| Battery input | Yes | Yes |
| Battery voltage | 48 V nominal (charge settings 48.0-62.0 V; MPPT range depends on PV) | - |
| Max charge current | 120 A | 120 A |
| Backup power | 6.2 kW | 6.2 kW |
| Weight | 10.0 kg | 10.7 kg |
| Weight per kW | 1.6 kg/kW | 1.7 kg/kW |
| Dimensions | - | 120x310x510 mm |
| Ingress protection | IP21 | - |
| Cooling | forced-air | forced-air |
| Noise | - | 50 dB |
| Max operating temperature | 55 °C | 50 °C |
| Wi-Fi | - | - |
| Ethernet | - | - |
| Arc fault protection | - | - |
| Integrated DC switch | - | - |
| Warranty | - | - |


## Related comparisons

- [Easun Power 6.2KVA (48V) vs Easun Power 6.2KVA (PVmax=500V, 48V battery)](https://comparepv.com/compare-inverters/easun-power-6-2kva-48v/easun-power-6-2kva-pvmax-500v-48v-battery) - 3 differences, the largest is weight
- [Easun Power 6.2KVA (48V) vs Easun Power POW-HVM6200W-48V](https://comparepv.com/compare-inverters/easun-power-6-2kva-48v/easun-power-pow-hvm6200w-48v) - One difference: weight
- [Easun Power 6.2KVA (48V) vs Easun Power POW-HVM6.2K-PRO (6.2KW)](https://comparepv.com/compare-inverters/easun-power-6-2kva-48v/easun-power-pow-hvm6-2k-pro-6-2kw) - 6 differences, the largest is max efficiency


---

Source: https://comparepv.com/compare-inverters/easun-power-6-2kva-48v/easun-power-pow-hvm6-2kp

Not in this file, on the page: a written summary generated on request.