{"id":711,"manufacturer":"Q-Cells","model_name":"Q.PEAK DUO RSF XL-G11S.3 / BFG 600","slug":"qcells-hanwha-q-cells-america-inc-q-peak-duo-rsf-xl-g11s-3-bfg-600","power_wp":600,"efficiency":21.5,"cell_type":"Monocrystalline","cell_technology":"PERC","cell_count":156,"dimensions_length_mm":2462,"dimensions_width_mm":1134,"dimensions_height_mm":35,"weight_kg":36.4,"warranty_performance_years":30,"warranty_end_percent":84.95,"degradation_first_year":2,"degradation_annual":0.45,"voc":53.66,"isc":13.8,"vmp":45.39,"imp":13.22,"temp_coeff_pmax":-0.34,"temp_coeff_voc":-0.27,"temp_coeff_isc":0.04,"noct":42,"max_system_voltage":1500,"datasheet_url":"/datasheets/qcells-data-sheet-q-peak-duo-rsf-xl-g11s-bfg-series-585-600-2f7abf296b19.pdf","datasheet_preview_url":"qcells-data-sheet-q-peak-duo-rsf-xl-g11s-bfg-series-585-600-2f7abf296b19.webp","series_image_url":"/static/images/panels/q-cells/q-peak-duo-rsf-xl-g11s-series.webp","series_name":"Q.PEAK DUO RSF XL-G11S SERIES","bifacial":true,"bifacial_gain":20,"bifaciality_factor":0.72,"connector_type":"Stäubli MC4","junction_box_ip":"IP68","description_en":"The Q-Cells Q.PEAK DUO RSF XL-G11S series are bifacial modules featuring a glass-glass structure, specifically designed for large ground installations, particularly on trackers. The most significant practical difference is the **robust steel frame (RSF)** with advanced anti-corrosion coating – it increases resistance to field conditions and facilitates achieving a stable structure under demanding loads. The series also focuses on **faster installation**: special positioning solutions help installation teams efficiently align the modules and minimize risks during the mounting phase.\n\nFrom the yield perspective, **bifacial capability** is key – the rear side of the module can genuinely contribute energy when the installation is on a light-colored ground surface or an asphalt surface with good reflectivity. Inside, Q.ANTUM monocrystalline cells operate, supported by **PID and LeTID protection, as well as Hot-Spot Protect**, making it easier to maintain performance over time. This is the choice for investors who prioritize LCOE, construction speed, and reliability, rather than just the specifications from the datasheet.","total_panels":14354,"rank_efficiency":8168,"rank_power_density":8244,"rank_temp_coeff":9020,"rank_weight":12800,"rank_warranty":31,"smart_insights":{"id":1462,"pv_panel_id":711,"insights_html":"\u003cul class=\"smart-insights\"\u003e\n  \u003cli data-icon=\"bi-lightning-charge-fill\"\u003e\u003ci class=\"bi bi-lightning-charge-fill\"\u003e\u003c/i\u003eEfficiency of 21.5% matches the \u003cstrong\u003ePERC 600-650W\u003c/strong\u003e median\u003c/li\u003e\n  \u003cli data-icon=\"bi-grid-3x3-gap-fill\"\u003e\u003ci class=\"bi bi-grid-3x3-gap-fill\"\u003e\u003c/i\u003eAt 214.9 W/m² power density, roof space requirements are typical for \u003cstrong\u003ePERC 600-650W\u003c/strong\u003e panels\u003c/li\u003e\n  \u003cli data-icon=\"bi-thermometer-half\"\u003e\u003ci class=\"bi bi-thermometer-half\"\u003e\u003c/i\u003eAt -0.34%/°C, hot weather performance is typical for \u003cstrong\u003ePERC 600-650W\u003c/strong\u003e panels\u003c/li\u003e\n  \u003cli data-icon=\"bi-box-seam-fill\"\u003e\u003ci class=\"bi bi-box-seam-fill\"\u003e\u003c/i\u003eAt 36.4 kg (2.4 kg above \u003cstrong\u003ePERC 600-650W\u003c/strong\u003e median of 34.0 kg), requires checking roof load capacity\u003c/li\u003e\n  \u003cli data-icon=\"bi-subtract\"\u003e\u003ci class=\"bi bi-subtract\"\u003e\u003c/i\u003eBifacial design (72% factor) captures reflected light - adds 4-11% yield on ground-mount or white roof\u003c/li\u003e\n\u003c/ul\u003e","insights_json":[{"text":"Efficiency of 21.5% matches the **PERC 600-650W** median","metric_key":"efficiency_percent","metric_value":21.5,"comparison":"at_median","delta":0.120000000000001,"icon":"bi-lightning-charge-fill"},{"text":"At 214.9 W/m² power density, roof space requirements are typical for **PERC 600-650W** panels","metric_key":"power_density_wp_m2","metric_value":214.91,"comparison":"at_median","delta":1.1099999999999852,"icon":"bi-grid-3x3-gap-fill"},{"text":"At -0.34%/°C, hot weather performance is typical for **PERC 600-650W** panels","metric_key":"temp_coeff_pmax","metric_value":-0.34,"comparison":"at_median","icon":"bi-thermometer-half"},{"text":"At 36.4 kg (2.4 kg above **PERC 600-650W** median of 34.0 kg), requires checking roof load capacity","metric_key":"weight_kg","metric_value":36.4,"comparison":"below_median","delta":2.3999999999999986,"icon":"bi-box-seam-fill"},{"text":"Bifacial design (72% factor) captures reflected light - adds 4-11% yield on ground-mount or white roof","metric_key":"bifaciality_factor","metric_value":72,"comparison":"bonus","icon":"bi-subtract"}],"insights_html_pl":"\u003cul class=\"smart-insights\"\u003e\n  \u003cli data-icon=\"bi-lightning-charge-fill\"\u003e\u003ci class=\"bi bi-lightning-charge-fill\"\u003e\u003c/i\u003eSprawność 21.5% odpowiada medianie \u003cstrong\u003ePERC 600-650W\u003c/strong\u003e\u003c/li\u003e\n  \u003cli data-icon=\"bi-grid-3x3-gap-fill\"\u003e\u003ci class=\"bi bi-grid-3x3-gap-fill\"\u003e\u003c/i\u003ePrzy gęstości mocy 214.9 W/m² wymagania powierzchni dachu są typowe dla paneli \u003cstrong\u003ePERC 600-650W\u003c/strong\u003e\u003c/li\u003e\n  \u003cli data-icon=\"bi-thermometer-half\"\u003e\u003ci class=\"bi bi-thermometer-half\"\u003e\u003c/i\u003ePrzy -0.34%/°C wydajność w gorące dni jest typowa dla paneli \u003cstrong\u003ePERC 600-650W\u003c/strong\u003e\u003c/li\u003e\n  \u003cli data-icon=\"bi-box-seam-fill\"\u003e\u003ci class=\"bi bi-box-seam-fill\"\u003e\u003c/i\u003ePrzy 36.4 kg (2.4 kg powyżej mediany \u003cstrong\u003ePERC 600-650W\u003c/strong\u003e 34.0 kg), wymaga sprawdzenia nośności dachu\u003c/li\u003e\n  \u003cli data-icon=\"bi-subtract\"\u003e\u003ci class=\"bi bi-subtract\"\u003e\u003c/i\u003eKonstrukcja bifacjalna (współczynnik 72%) wychwytuje odbite światło - dodaje 4-11% uzysku na gruncie lub białym dachu\u003c/li\u003e\n\u003c/ul\u003e","insights_json_pl":[{"text":"Sprawność 21.5% odpowiada medianie **PERC 600-650W**","metric_key":"efficiency_percent","metric_value":21.5,"comparison":"at_median","delta":0.120000000000001,"icon":"bi-lightning-charge-fill"},{"text":"Przy gęstości mocy 214.9 W/m² wymagania powierzchni dachu są typowe dla paneli **PERC 600-650W**","metric_key":"power_density_wp_m2","metric_value":214.91,"comparison":"at_median","delta":1.1099999999999852,"icon":"bi-grid-3x3-gap-fill"},{"text":"Przy -0.34%/°C wydajność w gorące dni jest typowa dla paneli **PERC 600-650W**","metric_key":"temp_coeff_pmax","metric_value":-0.34,"comparison":"at_median","icon":"bi-thermometer-half"},{"text":"Przy 36.4 kg (2.4 kg powyżej mediany **PERC 600-650W** 34.0 kg), wymaga sprawdzenia nośności dachu","metric_key":"weight_kg","metric_value":36.4,"comparison":"below_median","delta":2.3999999999999986,"icon":"bi-box-seam-fill"},{"text":"Konstrukcja bifacjalna (współczynnik 72%) wychwytuje odbite światło - dodaje 4-11% uzysku na gruncie lub białym dachu","metric_key":"bifaciality_factor","metric_value":72,"comparison":"bonus","icon":"bi-subtract"}],"model_used":"template-v1","generation_time_ms":9,"created_at":"2026-01-27T09:01:08.860323Z","updated_at":"2026-11-22T00:00:00.050844Z"},"series_info":{"discontinued":false,"release_year":2023,"discontinued_confidence":"high","release_year_confidence":"high","end_year_confidence":"high","source_notes":"The Q.PEAK DUO RSF (Reinforced Steel Frame) XL-G11S series was introduced in early 2023, with official installation manuals and datasheets (Revision 01) dating to February 2023. It is a specialized utility-scale module featuring a unique steel frame for tracker systems. As of late 2024, it remains in active production and was featured in the 2024 NREL Photovoltaic Reliability Workshop as part of Qcells' current utility portfolio. Recent datasheet updates (Revision 04) were published as late as mid-2024.","use_cases":["utility-scale","shaded-installations"],"use_cases_confidence":"high"}}