{"id":44663,"manufacturer":"Kyocera","model_name":"KU270-6MCA","slug":"kyocera-ku270-6mca","power_wp":270,"efficiency":16.41,"cell_type":"Polycrystalline","cell_count":60,"dimensions_length_mm":1662,"dimensions_width_mm":990,"dimensions_height_mm":46,"weight_kg":19,"voc":38.3,"isc":9.43,"vmp":31,"imp":8.71,"temp_coeff_pmax":-0.46,"temp_coeff_voc":-0.36,"temp_coeff_isc":0.06,"noct":45,"max_system_voltage":1000,"datasheet_url":"/datasheets/5df99f5fd8a14-3425a2d17584.pdf","datasheet_preview_url":"kyocera-5df99f5fd8a14.webp","series_name":"KU-60 1000V Series","bifacial":false,"frame_color":"Black","connector_type":"Amphenol H4-UTX","junction_box_ip":"IP65","description_en":"The Kyocera KU-60 1000V series are modules designed for installations operating at higher DC voltages – this makes it easier to build longer strings and reduce losses and the complexity of cabling in larger systems. This solution, based on \u003cb\u003emulti-crystalline solar cells\u003c/b\u003e, is designed for stable, predictable performance in real conditions on Polish roofs and PV farms. A key feature of this series is its robust design: \u003cb\u003ea rigid frame made of anodized aluminum\u003c/b\u003e provides mechanical strength, while factory-fitted \u003cb\u003eMC4\u003c/b\u003e connectors simplify installation and maintenance. Another important advantage in practical design is \u003cb\u003epositive power tolerance\u003c/b\u003e – this minimizes the risk that the actual output will be lower than expected. The KU-60 1000V will be suitable for installers and designers who want to optimize BOS balance in commercial, industrial, and ground-mounted installations, where string compatibility, parameter repeatability, and long-term reliability are important.","total_panels":14354,"rank_efficiency":13914,"rank_power_density":13906,"rank_temp_coeff":14226,"rank_weight":13760,"rank_warranty":14223,"smart_insights":{"id":3885,"pv_panel_id":44663,"insights_html":"\u003cul class=\"smart-insights\"\u003e\n  \u003cli data-icon=\"bi-lightning-charge-fill\"\u003e\u003ci class=\"bi bi-lightning-charge-fill\"\u003e\u003c/i\u003eModule efficiency of 16.4% is 5.4pp below average for \u003cstrong\u003edatabase\u003c/strong\u003e panels (median: 21.9%)\u003c/li\u003e\n  \u003cli data-icon=\"bi-grid-3x3-gap-fill\"\u003e\u003ci class=\"bi bi-grid-3x3-gap-fill\"\u003e\u003c/i\u003ePower density of 164.1 W/m² is 54.1 W/m² below \u003cstrong\u003edatabase\u003c/strong\u003e median (218.2 W/m²) - needs more roof space\u003c/li\u003e\n  \u003cli data-icon=\"bi-thermometer-half\"\u003e\u003ci class=\"bi bi-thermometer-half\"\u003e\u003c/i\u003e-0.46%/°C temperature coefficient - 0.16pp worse than \u003cstrong\u003edatabase\u003c/strong\u003e median (-0.30%/°C), expect higher hot weather losses\u003c/li\u003e\n  \u003cli data-icon=\"bi-box-seam-fill\"\u003e\u003ci class=\"bi bi-box-seam-fill\"\u003e\u003c/i\u003eAt 19.0 kg, this panel is 7.5 kg lighter than \u003cstrong\u003edatabase\u003c/strong\u003e median (26.5 kg) - easier handling during installation\u003c/li\u003e\n  \u003cli data-icon=\"bi-trophy-fill\"\u003e\u003ci class=\"bi bi-trophy-fill\"\u003e\u003c/i\u003e#13839 for efficiency, #14141 for temperature performance out of 14269 panels\u003c/li\u003e\n\u003c/ul\u003e","insights_json":[{"text":"Module efficiency of 16.4% is 5.4pp below average for **database** panels (median: 21.9%)","metric_key":"efficiency_percent","metric_value":16.41,"comparison":"below_median","delta":5.449999999999999,"icon":"bi-lightning-charge-fill"},{"text":"Power density of 164.1 W/m² is 54.1 W/m² below **database** median (218.2 W/m²) - needs more roof space","metric_key":"power_density_wp_m2","metric_value":164.1,"comparison":"below_median","delta":54.099999999999994,"icon":"bi-grid-3x3-gap-fill"},{"text":"-0.46%/°C temperature coefficient - 0.16pp worse than **database** median (-0.30%/°C), expect higher hot weather losses","metric_key":"temp_coeff_pmax","metric_value":-0.46,"comparison":"below_median","delta":0.16000000000000003,"icon":"bi-thermometer-half"},{"text":"At 19.0 kg, this panel is 7.5 kg lighter than **database** median (26.5 kg) - easier handling during installation","metric_key":"weight_kg","metric_value":19,"comparison":"above_median","delta":7.5,"icon":"bi-box-seam-fill"},{"text":"#13839 for efficiency, #14141 for temperature performance out of 14269 panels","metric_key":"ranking","metric_value":13839,"comparison":"bonus","icon":"bi-trophy-fill"}],"insights_html_pl":"\u003cul class=\"smart-insights\"\u003e\n  \u003cli data-icon=\"bi-lightning-charge-fill\"\u003e\u003ci class=\"bi bi-lightning-charge-fill\"\u003e\u003c/i\u003eSprawność modułu 16.4% jest o 5.4pp poniżej średniej dla paneli \u003cstrong\u003ebazy danych\u003c/strong\u003e (mediana: 21.9%)\u003c/li\u003e\n  \u003cli data-icon=\"bi-grid-3x3-gap-fill\"\u003e\u003ci class=\"bi bi-grid-3x3-gap-fill\"\u003e\u003c/i\u003eGęstość mocy 164.1 W/m² jest o 54.1 W/m² poniżej mediany \u003cstrong\u003ebazy danych\u003c/strong\u003e (218.2 W/m²) - wymaga więcej miejsca na dachu\u003c/li\u003e\n  \u003cli data-icon=\"bi-thermometer-half\"\u003e\u003ci class=\"bi bi-thermometer-half\"\u003e\u003c/i\u003eWspółczynnik temperaturowy -0.46%/°C - o 0.16pp gorszy od mediany \u003cstrong\u003ebazy danych\u003c/strong\u003e (-0.30%/°C), wyższe straty w upalne dni\u003c/li\u003e\n  \u003cli data-icon=\"bi-box-seam-fill\"\u003e\u003ci class=\"bi bi-box-seam-fill\"\u003e\u003c/i\u003ePrzy 19.0 kg ten panel jest o 7.5 kg lżejszy od mediany \u003cstrong\u003ebazy danych\u003c/strong\u003e (26.5 kg) - łatwiejszy montaż\u003c/li\u003e\n  \u003cli data-icon=\"bi-trophy-fill\"\u003e\u003ci class=\"bi bi-trophy-fill\"\u003e\u003c/i\u003e#13839 pod względem sprawności, #14141 pod względem wydajności temperaturowej z 14269 paneli\u003c/li\u003e\n\u003c/ul\u003e","insights_json_pl":[{"text":"Sprawność modułu 16.4% jest o 5.4pp poniżej średniej dla paneli **bazy danych** (mediana: 21.9%)","metric_key":"efficiency_percent","metric_value":16.41,"comparison":"below_median","delta":5.449999999999999,"icon":"bi-lightning-charge-fill"},{"text":"Gęstość mocy 164.1 W/m² jest o 54.1 W/m² poniżej mediany **bazy danych** (218.2 W/m²) - wymaga więcej miejsca na dachu","metric_key":"power_density_wp_m2","metric_value":164.1,"comparison":"below_median","delta":54.099999999999994,"icon":"bi-grid-3x3-gap-fill"},{"text":"Współczynnik temperaturowy -0.46%/°C - o 0.16pp gorszy od mediany **bazy danych** (-0.30%/°C), wyższe straty w upalne dni","metric_key":"temp_coeff_pmax","metric_value":-0.46,"comparison":"below_median","delta":0.16000000000000003,"icon":"bi-thermometer-half"},{"text":"Przy 19.0 kg ten panel jest o 7.5 kg lżejszy od mediany **bazy danych** (26.5 kg) - łatwiejszy montaż","metric_key":"weight_kg","metric_value":19,"comparison":"above_median","delta":7.5,"icon":"bi-box-seam-fill"},{"text":"#13839 pod względem sprawności, #14141 pod względem wydajności temperaturowej z 14269 paneli","metric_key":"ranking","metric_value":13839,"comparison":"bonus","icon":"bi-trophy-fill"}],"model_used":"template-v1","generation_time_ms":40,"created_at":"2026-01-27T09:01:08.860323Z","updated_at":"2026-11-20T00:00:00.107123Z"},"series_info":{"discontinued":true,"release_year":2015,"end_year":2022,"discontinued_confidence":"high","release_year_confidence":"high","end_year_confidence":"medium","source_notes":"Kyocera's KU-60 1000V Series (including models like KU265-6MCA and KU270-6MCA) was introduced in 2015, with official certifications (IEC 61215) and spec sheets appearing in April 2015. The series was discontinued in the North American market in 2016 when Kyocera exited that solar market. Global production of industrial panels, which included this series, effectively ended in September 2022 when Kyocera closed its commercial/industrial solar factory in Tianjin, China, to focus solely on the Japanese residential market.","use_cases":["commercial"],"use_cases_confidence":"high"}}