{"id":2616460,"manufacturer":"Gokin","model_name":"GK-4-78HGBD-780M","slug":"gokin-gk-4-78hgbd-780m","power_wp":780,"efficiency":24.3,"cell_type":"Monocrystalline","cell_technology":"Back Contact","cell_count":156,"dimensions_length_mm":2465,"dimensions_width_mm":1303,"dimensions_height_mm":33,"weight_kg":38.7,"warranty_product_years":15,"warranty_performance_years":30,"warranty_end_percent":88.85,"degradation_first_year":1,"degradation_annual":0.35,"voc":58.92,"isc":16.78,"vmp":48.97,"imp":15.93,"temp_coeff_pmax":-0.26,"temp_coeff_voc":-0.22,"temp_coeff_isc":0.05,"noct":45,"max_system_voltage":1500,"datasheet_url":"/datasheets/GK-4-78HGBD-SF-DG-F1_EN-1286e59862a6.pdf","datasheet_preview_url":"gokin-gk-4-78hgbd-sf-dg-f1-en.webp","series_image_url":"/static/images/panels/gokin/gk-4-78hgbd.webp","series_name":"GK-4-78HGBD","bifacial":true,"bifaciality_factor":0.7,"frame_color":"Anodized","connector_type":"MC4 Compatible","junction_box_ip":"IP68","description_en":"The Gokin GK-4-78HGBD series represents a breakthrough in efficiency thanks to the use of \u003cb\u003eN-type TOPCon technology\u003c/b\u003e, which eliminates the problem of light-induced degradation and guarantees stable operation for decades. The use of \u003cb\u003ebifacial dual glass construction\u003c/b\u003e allows for efficient energy harvesting not only directly from the sun but also from radiation reflected from the ground, which significantly increases the total annual energy yield. These modules solve the problem of limited installation space by offering high power density while maintaining exceptional resistance to extreme weather conditions, such as strong winds or snow loads. A distinguishing feature of the series is its excellent temperature coefficient, ensuring that the panels maintain high efficiency even on hot days when traditional cells lose performance. This solution is primarily dedicated to \u003cb\u003elarge-scale photovoltaic farms\u003c/b\u003e and demanding business installations where maximum return on investment and component durability are key. The Gokin GK-4-78HGBD stands out from the competition through precise optimization of the production process, which translates into \u003cb\u003eminimal losses at cell interconnections\u003c/b\u003e and better performance characteristics in low-light conditions. By choosing this series, investors gain technological certainty backed by an innovative 78-cell structure that redefines the standards of modern solar energy.","total_panels":14354,"rank_efficiency":173,"rank_power_density":182,"rank_temp_coeff":521,"rank_weight":3201,"rank_warranty":31,"smart_insights":{"id":2510465,"pv_panel_id":2616460,"insights_html":"\u003cul class=\"smart-insights\"\u003e\n  \u003cli data-icon=\"bi-lightning-charge-fill\"\u003e\u003ci class=\"bi bi-lightning-charge-fill\"\u003e\u003c/i\u003eEfficiency of 24.3% matches the \u003cstrong\u003eBack Contact 750-800W\u003c/strong\u003e median\u003c/li\u003e\n  \u003cli data-icon=\"bi-grid-3x3-gap-fill\"\u003e\u003ci class=\"bi bi-grid-3x3-gap-fill\"\u003e\u003c/i\u003eAt 242.8 W/m² power density, roof space requirements are typical for \u003cstrong\u003eBack Contact 750-800W\u003c/strong\u003e panels\u003c/li\u003e\n  \u003cli data-icon=\"bi-thermometer-half\"\u003e\u003ci class=\"bi bi-thermometer-half\"\u003e\u003c/i\u003eTemperature coefficient of -0.26%/°C matches the \u003cstrong\u003eBack Contact 750-800W\u003c/strong\u003e median\u003c/li\u003e\n  \u003cli data-icon=\"bi-box-seam-fill\"\u003e\u003ci class=\"bi bi-box-seam-fill\"\u003e\u003c/i\u003eAt 38.7 kg, this panel is 1.1 kg lighter than \u003cstrong\u003eBack Contact 750-800W\u003c/strong\u003e median (39.8 kg) - easier handling during installation\u003c/li\u003e\n  \u003cli data-icon=\"bi-subtract\"\u003e\u003ci class=\"bi bi-subtract\"\u003e\u003c/i\u003e70% bifaciality enables rear-side power generation, boosting yield by 4-10% on reflective surfaces\u003c/li\u003e\n\u003c/ul\u003e","insights_json":[{"text":"Efficiency of 24.3% matches the **Back Contact 750-800W** median","metric_key":"efficiency_percent","metric_value":24.3,"comparison":"at_median","delta":0.1999999999999993,"icon":"bi-lightning-charge-fill"},{"text":"At 242.8 W/m² power density, roof space requirements are typical for **Back Contact 750-800W** panels","metric_key":"power_density_wp_m2","metric_value":242.85,"comparison":"at_median","delta":1.549999999999983,"icon":"bi-grid-3x3-gap-fill"},{"text":"Temperature coefficient of -0.26%/°C matches the **Back Contact 750-800W** median","metric_key":"temp_coeff_pmax","metric_value":-0.26,"comparison":"at_median","icon":"bi-thermometer-half"},{"text":"At 38.7 kg, this panel is 1.1 kg lighter than **Back Contact 750-800W** median (39.8 kg) - easier handling during installation","metric_key":"weight_kg","metric_value":38.7,"comparison":"above_median","delta":1.0999999999999943,"icon":"bi-box-seam-fill"},{"text":"70% bifaciality enables rear-side power generation, boosting yield by 4-10% on reflective surfaces","metric_key":"bifaciality_factor","metric_value":70,"comparison":"bonus","icon":"bi-subtract"}],"insights_html_pl":"\u003cul class=\"smart-insights\"\u003e\n  \u003cli data-icon=\"bi-lightning-charge-fill\"\u003e\u003ci class=\"bi bi-lightning-charge-fill\"\u003e\u003c/i\u003eSprawność 24.3% odpowiada medianie \u003cstrong\u003eBack Contact 750-800W\u003c/strong\u003e\u003c/li\u003e\n  \u003cli data-icon=\"bi-grid-3x3-gap-fill\"\u003e\u003ci class=\"bi bi-grid-3x3-gap-fill\"\u003e\u003c/i\u003ePrzy gęstości mocy 242.8 W/m² wymagania powierzchni dachu są typowe dla paneli \u003cstrong\u003eBack Contact 750-800W\u003c/strong\u003e\u003c/li\u003e\n  \u003cli data-icon=\"bi-thermometer-half\"\u003e\u003ci class=\"bi bi-thermometer-half\"\u003e\u003c/i\u003eWspółczynnik temperaturowy -0.26%/°C odpowiada medianie \u003cstrong\u003eBack Contact 750-800W\u003c/strong\u003e\u003c/li\u003e\n  \u003cli data-icon=\"bi-box-seam-fill\"\u003e\u003ci class=\"bi bi-box-seam-fill\"\u003e\u003c/i\u003ePrzy 38.7 kg ten panel jest o 1.1 kg lżejszy od mediany \u003cstrong\u003eBack Contact 750-800W\u003c/strong\u003e (39.8 kg) - łatwiejszy montaż\u003c/li\u003e\n  \u003cli data-icon=\"bi-subtract\"\u003e\u003ci class=\"bi bi-subtract\"\u003e\u003c/i\u003e70% bifacjalność umożliwia generowanie mocy z tyłu, zwiększając uzysk o 4-10% na odblaskowych powierzchniach\u003c/li\u003e\n\u003c/ul\u003e","insights_json_pl":[{"text":"Sprawność 24.3% odpowiada medianie **Back Contact 750-800W**","metric_key":"efficiency_percent","metric_value":24.3,"comparison":"at_median","delta":0.1999999999999993,"icon":"bi-lightning-charge-fill"},{"text":"Przy gęstości mocy 242.8 W/m² wymagania powierzchni dachu są typowe dla paneli **Back Contact 750-800W**","metric_key":"power_density_wp_m2","metric_value":242.85,"comparison":"at_median","delta":1.549999999999983,"icon":"bi-grid-3x3-gap-fill"},{"text":"Współczynnik temperaturowy -0.26%/°C odpowiada medianie **Back Contact 750-800W**","metric_key":"temp_coeff_pmax","metric_value":-0.26,"comparison":"at_median","icon":"bi-thermometer-half"},{"text":"Przy 38.7 kg ten panel jest o 1.1 kg lżejszy od mediany **Back Contact 750-800W** (39.8 kg) - łatwiejszy montaż","metric_key":"weight_kg","metric_value":38.7,"comparison":"above_median","delta":1.0999999999999943,"icon":"bi-box-seam-fill"},{"text":"70% bifacjalność umożliwia generowanie mocy z tyłu, zwiększając uzysk o 4-10% na odblaskowych powierzchniach","metric_key":"bifaciality_factor","metric_value":70,"comparison":"bonus","icon":"bi-subtract"}],"model_used":"template-v1","generation_time_ms":31,"created_at":"2026-04-01T05:44:49.418414Z","updated_at":"2026-11-20T18:00:00.020772Z"},"series_info":{"discontinued":false,"release_year":2025,"discontinued_confidence":"high","release_year_confidence":"high","end_year_confidence":"low","source_notes":"pv-magazine.com 2025-12-15 launch article; gokinsolar.com/en/GOKIN-BC-Series official product page; solarfacts.in coverage of 780W BC module launch at Gokin Solar Global BC Eco Summit (Guangzhou, December 2025).","use_cases":["utility-scale","commercial","hot-climate"],"use_cases_confidence":"medium"}}