{"id":8859943,"manufacturer":"Canadian Solar","model_name":"CS3K-325MB-AG","slug":"canadian-solar-cs3k-325mb-ag","power_wp":325,"efficiency":19.3,"cell_type":"Monocrystalline","cell_technology":"PERC","cell_count":120,"dimensions_length_mm":1696,"dimensions_width_mm":992,"dimensions_height_mm":30,"weight_kg":22.3,"warranty_product_years":12,"warranty_performance_years":30,"voc":40.3,"isc":10.22,"vmp":33.5,"imp":9.71,"temp_coeff_pmax":-0.36,"temp_coeff_voc":-0.29,"temp_coeff_isc":0.05,"noct":41,"max_system_voltage":1500,"datasheet_url":"/datasheets/Canadian_Solar-Datasheet-BiKu_CS3K-MB-AG_EN-b9610f91e466.pdf","datasheet_preview_url":"canadian-solar-datasheet-biku-cs3k-mb-ag-en-b9610f91e466.webp","series_image_url":"/static/images/panels/canadian-solar/biku-cs3k-mb-ag.webp","series_name":"BiKu CS3K-MB-AG","bifacial":true,"bifacial_gain":30,"bifaciality_factor":0.7,"connector_type":"T4 series or H4 UTX or MC4-EVO2","junction_box_ip":"IP68","description_en":"The BiKu CS3K-MB-AG series is a bifacial photovoltaic module lineup from Canadian Solar engineered to squeeze extra output from every ray of sunlight. These panels use \u003cb\u003ebifacial technology\u003c/b\u003e with a dual tempered glass construction instead of a rear backsheet, allowing the module to generate power from both sides and capture additional energy reflected off the ground. The \u003cb\u003emonocrystalline PERC half-cut cells\u003c/b\u003e, arranged in a 120-cell layout and connected with MBB or 5BB busbar technology, reduce resistive losses and improve \u003cb\u003epartial shading tolerance\u003c/b\u003e. The dual-glass design removes the frame's exposure to degradation, boosts mechanical resistance to heavy snow and wind loads, and extends system lifespan, contributing to a \u003cb\u003elower levelized cost of energy (LCOE)\u003c/b\u003e. A low power temperature coefficient means the module retains more output on hot days, which matters for rooftop installations with limited ventilation. The BiKu series fits both rooftop and ground-mount projects, especially where light-colored surfaces or gravel maximize rear-side energy gain. It's a strong choice for investors looking to boost yield per square meter of roof space without adding more modules, all while relying on the proven, field-tested reliability of standard mono-PERC silicon technology.","total_panels":14354,"rank_efficiency":13093,"rank_power_density":13072,"rank_temp_coeff":12629,"rank_weight":13668,"rank_warranty":31,"smart_insights":{"id":8605913,"pv_panel_id":8859943,"insights_html":"\u003cul class=\"smart-insights\"\u003e\n  \u003cli data-icon=\"bi-lightning-charge-fill\"\u003e\u003ci class=\"bi bi-lightning-charge-fill\"\u003e\u003c/i\u003eAt 19.3% efficiency, this panel is on par with typical \u003cstrong\u003ePERC 0-400W\u003c/strong\u003e modules\u003c/li\u003e\n  \u003cli data-icon=\"bi-grid-3x3-gap-fill\"\u003e\u003ci class=\"bi bi-grid-3x3-gap-fill\"\u003e\u003c/i\u003eAt 193.2 W/m² power density, roof space requirements are typical for \u003cstrong\u003ePERC 0-400W\u003c/strong\u003e panels\u003c/li\u003e\n  \u003cli data-icon=\"bi-thermometer-half\"\u003e\u003ci class=\"bi bi-thermometer-half\"\u003e\u003c/i\u003eAt -0.36%/°C, hot weather performance is typical for \u003cstrong\u003ePERC 0-400W\u003c/strong\u003e panels\u003c/li\u003e\n  \u003cli data-icon=\"bi-box-seam-fill\"\u003e\u003ci class=\"bi bi-box-seam-fill\"\u003e\u003c/i\u003eAt 22.3 kg (1.9 kg above \u003cstrong\u003ePERC 0-400W\u003c/strong\u003e median of 20.4 kg), requires checking roof load capacity\u003c/li\u003e\n  \u003cli data-icon=\"bi-subtract\"\u003e\u003ci class=\"bi bi-subtract\"\u003e\u003c/i\u003e70% bifaciality enables rear-side power generation, boosting yield by 4-10% on reflective surfaces\u003c/li\u003e\n\u003c/ul\u003e","insights_json":[{"text":"At 19.3% efficiency, this panel is on par with typical **PERC 0-400W** modules","metric_key":"efficiency_percent","metric_value":19.3,"comparison":"at_median","delta":0.09999999999999787,"icon":"bi-lightning-charge-fill"},{"text":"At 193.2 W/m² power density, roof space requirements are typical for **PERC 0-400W** panels","metric_key":"power_density_wp_m2","metric_value":193.17,"comparison":"at_median","delta":0.8300000000000125,"icon":"bi-grid-3x3-gap-fill"},{"text":"At -0.36%/°C, hot weather performance is typical for **PERC 0-400W** panels","metric_key":"temp_coeff_pmax","metric_value":-0.36,"comparison":"at_median","icon":"bi-thermometer-half"},{"text":"At 22.3 kg (1.9 kg above **PERC 0-400W** median of 20.4 kg), requires checking roof load capacity","metric_key":"weight_kg","metric_value":22.3,"comparison":"below_median","delta":1.9000000000000021,"icon":"bi-box-seam-fill"},{"text":"70% bifaciality enables rear-side power generation, boosting yield by 4-10% on reflective surfaces","metric_key":"bifaciality_factor","metric_value":70,"comparison":"bonus","icon":"bi-subtract"}],"insights_html_pl":"\u003cul class=\"smart-insights\"\u003e\n  \u003cli data-icon=\"bi-lightning-charge-fill\"\u003e\u003ci class=\"bi bi-lightning-charge-fill\"\u003e\u003c/i\u003ePrzy sprawności 19.3% ten panel jest na poziomie typowych modułów \u003cstrong\u003ePERC 0-400W\u003c/strong\u003e\u003c/li\u003e\n  \u003cli data-icon=\"bi-grid-3x3-gap-fill\"\u003e\u003ci class=\"bi bi-grid-3x3-gap-fill\"\u003e\u003c/i\u003ePrzy gęstości mocy 193.2 W/m² wymagania powierzchni dachu są typowe dla paneli \u003cstrong\u003ePERC 0-400W\u003c/strong\u003e\u003c/li\u003e\n  \u003cli data-icon=\"bi-thermometer-half\"\u003e\u003ci class=\"bi bi-thermometer-half\"\u003e\u003c/i\u003ePrzy -0.36%/°C wydajność w gorące dni jest typowa dla paneli \u003cstrong\u003ePERC 0-400W\u003c/strong\u003e\u003c/li\u003e\n  \u003cli data-icon=\"bi-box-seam-fill\"\u003e\u003ci class=\"bi bi-box-seam-fill\"\u003e\u003c/i\u003ePrzy 22.3 kg (1.9 kg powyżej mediany \u003cstrong\u003ePERC 0-400W\u003c/strong\u003e 20.4 kg), wymaga sprawdzenia nośności dachu\u003c/li\u003e\n  \u003cli data-icon=\"bi-subtract\"\u003e\u003ci class=\"bi bi-subtract\"\u003e\u003c/i\u003e70% bifacjalność umożliwia generowanie mocy z tyłu, zwiększając uzysk o 4-10% na odblaskowych powierzchniach\u003c/li\u003e\n\u003c/ul\u003e","insights_json_pl":[{"text":"Przy sprawności 19.3% ten panel jest na poziomie typowych modułów **PERC 0-400W**","metric_key":"efficiency_percent","metric_value":19.3,"comparison":"at_median","delta":0.09999999999999787,"icon":"bi-lightning-charge-fill"},{"text":"Przy gęstości mocy 193.2 W/m² wymagania powierzchni dachu są typowe dla paneli **PERC 0-400W**","metric_key":"power_density_wp_m2","metric_value":193.17,"comparison":"at_median","delta":0.8300000000000125,"icon":"bi-grid-3x3-gap-fill"},{"text":"Przy -0.36%/°C wydajność w gorące dni jest typowa dla paneli **PERC 0-400W**","metric_key":"temp_coeff_pmax","metric_value":-0.36,"comparison":"at_median","icon":"bi-thermometer-half"},{"text":"Przy 22.3 kg (1.9 kg powyżej mediany **PERC 0-400W** 20.4 kg), wymaga sprawdzenia nośności dachu","metric_key":"weight_kg","metric_value":22.3,"comparison":"below_median","delta":1.9000000000000021,"icon":"bi-box-seam-fill"},{"text":"70% bifacjalność umożliwia generowanie mocy z tyłu, zwiększając uzysk o 4-10% na odblaskowych powierzchniach","metric_key":"bifaciality_factor","metric_value":70,"comparison":"bonus","icon":"bi-subtract"}],"model_used":"template-v1","generation_time_ms":12,"created_at":"2026-07-30T06:00:00.145574Z","updated_at":"2026-11-21T18:00:00.074895Z"},"series_info":{"discontinued":true,"release_year":2018,"end_year":2021,"discontinued_confidence":"medium","release_year_confidence":"low","end_year_confidence":"medium","source_notes":"Canadian Solar official datasheet PDFs for BiKu CS3K-MB-AG (dated 2019-2020, static.csisolar.com/canadiansolar.com), ENF Solar panel directory listings noting the model as no longer in current production, and comparison with Canadian Solar's current catalog which now features the larger-format BiHiKu6/BiHiKu7 and TOPBiHiKu6/7 Gen6+ module lines as the active bifacial products (canadiansolar.com/biku/, /bihiku6/).","use_cases":["residential","commercial"],"use_cases_confidence":"medium"}}